background image

Range hood

DW-SM9

Operating instructions

V-ZUG Ltd

 

Summary of Contents for DW-SM9

Page 1: ...Range hood DW SM9 Operating instructions V ZUG Ltd...

Page 2: ...The right to make technical modifications for the purpose of the further development of the appliance is reserved Symbols used A Indicates step by step instructions Describes how the appliance reacts...

Page 3: ...0 Construction 11 Operating and display elements 12 Use 13 Operation 13 Intensive level 14 Illumination 14 Saturation indicator 15 Care and maintenance 16 Cleaning the housing 16 Cleaning the grease f...

Page 4: ...Contents 4 Accessories and spare parts 24 Technical data 25 Disposal 26 Notes 27 Index 29 Repair service 31 Quick instructions 32...

Page 5: ...ty Before using for the first time The appliance must be installed and connected up to the electricity supply according to the separate installation instructions The necessary work should be carried o...

Page 6: ...necessary Use original spare parts only Retain these operating instructions for future reference If you sell or pass the appliance on to a third party please ensure these operating instruc tions toge...

Page 7: ...ping it below the temperature at which it can catch fire Change the cooking oil regularly dirty oil catches fire more easily than clean oil Clean the filters regularly Failure to do so can increase th...

Page 8: ...fresh air must be guaranteed e g via non closable openings in doors and windows and combined with ventilation wall bricks for incoming and exhaust air or by other technical means When carrying out ma...

Page 9: ...ed through the combi filters and metal grease filters and passed through a pipe with an integrated non return valve and then through an air duct to the outside Recirculation mode The cooking fumes and...

Page 10: ...ilter The extraction fan has 4 power levels 1 Low 2 Medium 3 High and Intensive level Power levels 1 3 can be used for longer periods of operation The intensive level is for shorter bursts of intensiv...

Page 11: ...Appliance description 11 Construction 1 Operating elements 2 Halogen light 3 Combi filter 4 Metal grease filter 5 Activated charcoal filter 6 Profile slot 2 4 3 1 5 6...

Page 12: ...mination Off On Power level 1 Power level 2 Saturation indicator for metal grease filters combi fil ters and long life activated charcoal filter Power level 3 Saturation indicator for standard activat...

Page 13: ...ich power level is currently being used Switching the appliance off A Press the button to switch the appliance off We recommend switching the appliance on at power level 1 some 5 minutes before cookin...

Page 14: ...e level before the 5 minutes is up Illumination A Press the button to switch the illumination on A Press the button to switch the illumination off If a different power level had been running beforehan...

Page 15: ...el is reached the standard activated charcoal filter needs to be replaced To activate the saturation indicator A Depress the and buttons at the same time for 3 seconds The indicator light flashes Afte...

Page 16: ...condensate water can build up around the combi filters on the inside A Clean using a slightly damp cloth and detergent if necessary and wipe dry Take care that no water gets into the housing of the a...

Page 17: ...grease filters can be cleaned in a dishwasher A Select an intensive or heavy soil wash programme with a warm pre wash If you do not have a dishwasher A Clean the grease filters in the sink with hot wa...

Page 18: ...grease filter push the grip 2 back A Carefully pull the metal grease filter down and out of the holder Replacing the metal grease filters and the combi filters A Replace the metal grease filters A Put...

Page 19: ...e grease filters A Turn both knobs A 90 and remove the standard activated charcoal filter from the bottom A Insert the new standard activated char coal filter and secure at the front with both knobs A...

Page 20: ...ogramme Wash the filter separately so that it does not become clogged with food particles If it is not possible to wash the filter in a dishwasher soak the filter in 60 C water and detergent for one h...

Page 21: ...care not to damage the filter If necessary replace the used long life acti vated charcoal filter by a new one A Replace the long life activated charcoal filter and engage it at the back and secure at...

Page 22: ...me type max 20 watts A Clean the ring and the glass A Fit the ring and the glass back into the openings A Put screw fuse back in or switch circuit breaker on again Remove screw fuse or switch off circ...

Page 23: ...home is faulty A Change the fuse A Reset the circuit breaker Interruption in the power supply A Check the power supply The halogen light is faulty A Change the halogen light Possible cause Solutions...

Page 24: ...number and exact description when ordering parts Halogen light Metal grease filter Standard activated charcoal filter Long life activated charcoal filter Combi filter Middle Left Right The halogen li...

Page 25: ...25 Technical data Electrical connection A See identification plate A Remove metal grease filter The identification plate is located on the inside of the appliance...

Page 26: ...cket or have the appliance disconnected from the mains by a qualified electrician Then cut off the mains cable Disposal The old appliance should not be discarded as worthless rubbish If disposed of co...

Page 27: ...27 Notes...

Page 28: ...Notes 28...

Page 29: ...mode 9 F Filter 11 Activated charcoal filter 19 Combi filter 17 Metal grease filter 17 Fittings 10 H Halogen light 11 22 I Identification plate 25 Illumination 14 Intensive level 14 L Long life activa...

Page 30: ...use 6 Note on use 7 Saturation indicator 15 Selecting the power level 13 Service agreement 31 Service centre 31 Spare parts 24 Ordering 31 Standard activated charcoal filter 19 Saturation indicator 15...

Page 31: ...If the appliance is not working properly contact your nearest V ZUG Ltd service centre using freephone 0800 850 850 and stand in close proximity to the appliance Queries orders service agreement For a...

Page 32: ...erating instructions Operation Illumination Switch off Reset saturation indicator Switch on Power level Intensive Off On J330 13 6 V ZUG Ltd Industriestrasse 66 6301 Zug Tel 41 0 41 767 67 67 Fax 41 0...

Reviews: