Settings options for the saturation indicator
Amount of
activated
charcoal
Cooking intensity
Operating
hours
Power level
display
5 kg
Standard, for not overly frequent
and/or pungent cooking
1200 h
5 kg
For more frequent and/or more
pungent cooking
700 h
2.5 kg
Standard, for not overly frequent
and/or pungent cooking
700 h
2.5 kg
For more frequent and/or more
pungent cooking
400 h
If the appliance is to be used as an extraction model, the hours counter for the
activated charcoal filters must be deactivated.
Deactivating the saturation indicator for the activated charcoal filters
Switch the appliance off.
Depress the button for 3 seconds.
– The and displays flash.
Depress the button again for 3 seconds.
– The and displays go out.
The range hood is now set up as an extraction model.
4 Operating the appliance
14