4
Operating the appliance
4.1
Using for the first time
Configuring the appliance
The appliance can be used in the extraction or recirculation mode. The appli-
ance is set up as a recirculation hood with 5 kg of activated charcoal ex-
factory. With this setting, the service life of the activated charcoal filter is 1,200
operating hours. The operating hours counter must be configured for the
version of the range hood with 2.5 kg of activated charcoal. The saturation
indicator can also be adjusted to your cooking habits.
If the appliance is to be used as an extraction model, the saturation
indicator for the activated charcoal filter must be deactivated.
Amount of activated charcoal used
Remove the grease filters (see
Cleaning the grease filters).
– For the length of the motor
housing, see on the inside (see
arrow).
Short motor housing = 2.5 kg activated charcoal
Long motor housing = 5 kg activated charcoal
Activating and changing the saturation indicator for the activated charcoal
filter
Switch the appliance off.
Depress the button for 3 seconds.
– The and displays flash.
Press the button repeatedly until the desired setting illuminates in the
display.
– The setting selected will be automatically accepted after 5 seconds.
The range hood is now set up as a recirculation model.
13
Summary of Contents for DWPQG Series
Page 1: ...V ZUG Ltd Range hood DWPQG DIPQG Operating instructions ...
Page 27: ...9 Notes 27 ...
Page 28: ...9 Notes 28 ...