Installation instructions

Room air laundry dryer
One-family household

1064364-07

04/10/2022

1064364-07

1

Validity

The installation instructions apply to the model: 

12014

Warnings

The appliance should be installed by qualified personnel only.
Each step must be carried out and checked in full in the order specified.

Check the appliance for visible damage. Do not use the appliance if it is damaged in any way.

Transport the appliance in an upright position only! Transporting it in any other position will result in damage to the
appliance! When carried carefully without being shaken, the appliance may be tilted a maximum of 90° to the left
(viewed from the front).

Do not connect this appliance

to a voltage source that is controlled by an external device such as a time switch, timer or device that regularly switches
the voltage to the outlet on and off (as in the case of a 

Mittagssperre or midday power shut-off),

or to a voltage source that is switched by a CoinSystem 1, CoinSystem 2, CardSystem 1, CardSystem 2 or VESTA cash-
ier system from V-ZUG Ltd.

Room size, room climate and ventilation

Keep all ventilation slits on the appliance clear and unobstructed. Otherwise an adequate supply of air is not guaran-
teed.

For the tumble drying operating mode: Ensure that the temperature of the room is between 5–35 °C.

For the room air drying operating mode: Ensure that the temperature of the room is between 8–35 °C.

The room temperature must be kept between the range of 15–25 °C to ensure the economic running of the appliance.

For the tumble drying operating mode 

Room size <10 m² (<20 m³)

Room size 10-25 m²(20-50 m³)

Room must be ventilated

: There

must be air inlet and outlet openings
to the adjacent room or to the out-
side, e.g. open window/door, ventil-
ation grille or slits in the door or
ventilation system.

Condensation may form on thermal
bridges! The room must therefore
be aired after running several con-
secutive drying programmes, e.g.
by opening a window or door to the
room.

For the room air drying operating mode 

Room size ≤25 m² (≤50 m³)

Doors to and windows in the room
must be kept closed during the dry-
ing process.

If a room ≥25 m² (≥50 m

3

), the laun-

dry cannot be guaranteed to have
reached the desired level of dryness
when the programme ends.

Summary of Contents for V4000 DualDry

Page 1: ...STA cash ier system from V ZUG Ltd Room size room climate and ventilation Keep all ventilation slits on the appliance clear and unobstructed Otherwise an adequate supply of air is not guaran teed For...

Page 2: ...on plate Open the appliance door The identification plate 1 is located bottom right 1 Installation accessories supplied The necessary installation accessories are located in the washing drum and in th...

Page 3: ...surrounding walls of their installation location 595 70 15 600 500 50 58 2 6 1 4 126 444 280 850 5 550 458 71 3 1 Cooling air inlet 2 Installation plate 3 Cooling air outlet 4 Outlet mains connection...

Page 4: ...d niche depth B based on the niche variants Use two ventilation grilles P33002 or provide a ventilation cross section 1 of min 400 cm2 to conduct the heat that is emitted from the rear of the applianc...

Page 5: ...rve the distance to the back and side walls this applies to indi vidual appliances as well as to a tumble dryer and washing machine positioned next to each other The installation plates for the tumble...

Page 6: ...pe of the manufacturer s guarantee For washing machine models 11001 11006 11010 11014 11021 11023 11025 Take out the double sided adhesive tape 1 and adhere to the mount ing surfaces 2 1 2 2 2 2 For w...

Page 7: ...parts and cables with basic insulation must not be accessible Check old installa tions Use at altitude Electrical safety is guaranteed up to 2 000 m above sea level Refer to the identification plate...

Page 8: ...n kit W56298 Use an open top fixed upright outflow pipe with the drain trap Leave a gap of 5 cm between the end of the drain hose from the tumble dryer and the level of the water in the drain trap Pos...

Page 9: ...asher dryer towers Can be connected to a concealed double drain trap Use an open top fixed upright outflow pipe with the drain trap Route drainage pipe separately or use condensate drain kit W55969 70...

Page 10: ...be selected and the appliance enters the normal operating mode The function test can be carried out regardless of the position of the air inlet and outlet flaps Carrying out the function test Insert...

Reviews: