21
GATE DELAY DURING CLOSING
In order to avoid the colliding of gate's during the closing the
time of delay should de introduced r.Ch, which is adjustable
from 0 to 2 minutes. In such a case the closing time of
gate1 is delayed in comparison to the gate2.
BACKLASH TIME
To help release the electric lock it is possible to set an
inversion time, ranging from 0 to 3 seconds.
During inversion time motors are driven in the closing direc-
tion while lock is operated. If you set an inversion time grea-
ter than lock time, motors are driven in the closing direction
only while the lock time lasts.
PRE-FLASHING TIME
This menu permits the introduction of a pre-flashing that
occurs before any movement of the gate either in opening or
in closing phase: the time of pre-flashing can be adjusted
from 0 to 2 minutes.
END OF STROKE SLOWING DOWN
Such a menu allows enabling the door slowing down at their
end of stroke by means of two speeds which can be set up
according to your needs.
vEL1
corresponds to 25% of power.
vEL2
corresponds to 50% of power.
MOTOR 1 POWER
Such a menu enables the sensitivity adjusting of the motor 1
current sensor from 1A to 7A.
START SLOWING DOWN
Such a menu enables the motor slowing down start as for
the opening and closing phase.
MOTOR 2 POWER
Such a menu enables the sensitivity adjusting of the motor 1
current sensor from 1A to 7A.
LOCK TIME
Before the opening phase starts, the gearcase has to energi-
ze the electrical lock in order to release it and enable the
gate movement. The time t.SEr determines the duration of
excitation, and is adjustable from 0 to 3 seconds. In case
there is no motor lock, set up on
no
.
Summary of Contents for City2
Page 2: ...City2 ISTRUZIONI 1 INSTRUCTIONS 15 NOTICES 29 ANLEITUNGEN 43 INSTRUCCIONES 57 I GB F D E ...
Page 16: ...14 NOTE ...
Page 30: ...28 NOTE ...
Page 44: ...42 NOTA ...
Page 58: ...56 BEMERKUNGEN ...
Page 72: ...70 NOTA ...