24
PHOTO 1 INPUT
This input can be activated for the connection of two different
safety devices: the photocell or the rib. The rib (contact nor-
mally closed) is an active safety device in opening and clo-
sing (now active during the backlash): its intervention during
the opening phase stops the gate, inverts the motion for 4 s,
without offsetting the doors. On the other hand, the interven-
tion of the rib in closing phase stops the gate, inverts the
motion with the offset of the doors. The photocell 1 (contact
normally closed) is an active security in opening and closing:
the intervention of the photocell during the closing stops the
gate, at its disengagement the gate inverts the motion.
Differently the intervention of the photocell in opening stops
the gate, at its disengagement the gate starts opening again.
It is necessary to install the photocell 1 properly, in order to
cover the action space of the gate.
no
the opening of PHOTO1 is not available
Cost
the opening of PHOTO 1 is available for the connection
of the rib.
APCh
the opening of PHOTO 1 is available for the connection
of the photocell
TIMER FUNCTION
This function permits to program the time bands of opening
and closing. It is necessary to connect a 24h timer with a
contact normally open in parallel with the START or PEDE-
STRIAN START input. When the timer contact is closed, the
gate gets into opening phase and remains opened until the
contact of the timer opens causing the re-closing of the gate.
m
IMPORTANT
: for a correct functioning it is necessary to
activate the automatic closing (menu Ch.AU.)
FLASHLIGHT WITH INTERMITTENCE
The control unit
City2
permits the connection of a flashlight
with or without intermittence. If the flashlight is equipped with
an inner intermittence effect, it is necessary to select the
option "Si", but if it has no inner intermittence, it is neces-
sary to select the option "no" in order to make it flash.
STOP INPUT
This menu permits to select the functions associated to the
command of STOP.
no
the input STOP is not available
ProS
the input STOP stops the gate: pressing the command
START the gate continues the motion
invE
the command STOP stops the gate: at the next START
the gate starts moving in the opposite direction.
NOTE: during the pause, the STOP command will stop the
pause time count, the next START command will always close
the gate.
Summary of Contents for City2
Page 2: ...City2 ISTRUZIONI 1 INSTRUCTIONS 15 NOTICES 29 ANLEITUNGEN 43 INSTRUCCIONES 57 I GB F D E ...
Page 16: ...14 NOTE ...
Page 30: ...28 NOTE ...
Page 44: ...42 NOTA ...
Page 58: ...56 BEMERKUNGEN ...
Page 72: ...70 NOTA ...