Automatic closing
In automatic mode, the control unit automatically recloses the gate on
expiry of the time limit set in this menu.
The Start command, if enabled by
St.PA
menu, allows closing the gate
before the set up time expires.
In semi-automatic operation, that is to say, if the automatic closing
function is disabled by setting the value to zero (
no
will be displayed),
the gate can be closed through the start command only: in this case,
St.PA
menu setup will be ignored.
If the control unit receives a Stop command when the gate is in pause,
it will automatically pass to the semi-automatic operation.
Closing after transit
During the automatic operation, the pause count down starts from the
set up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing as soon as transit through the
gate is completed, therefore, a time shorter than
Ch.AU
is generally
used.
Ch.AU
will be used when
no
is set up.
As for semi-automatic operation, this function is not active.
Pause after transit
In order to let the gate open for the shortest possible time, it is possible
to stop the gate once the passage before the photocells is detected. If
the automatic working is enabled, the time of the pause is
Ch.tr
.
If interior and exterior photocells are installed, the gate only pauses after
passing in front of both has been detected.
Courtesy lights
This menu allows setting the automatic operating
of the courtesy lights during the opening cycle of
the gate.
NOTE:
If the output is used to drive a flashing
light (with internal flasher) select
CiCL
.
t.LUC
the relay is enabled at the receiving of a control of start or pedestrian start; choosing this option, a submenu is entered - it allows
to set the length of the activation of the relay from 0.0” to 20’0 (default 1’00). At the time limit, the relay is disabled.
no
the relay of the courtesy lights is not automatically activated
CiCL
the relay is activated during the motion of the gate; when the gate stops (closed or open) the relay is on all the time
t.LUC
long
(set in the submenu
t.LUC
).
If the option
LP.PA
is activated, the relay is on also during the pause time