E
N
G
L
IS
H
59
Auxiliary channel
This menu allows setting the operating of the relay of the lighting of the
courtesy lights by means of a remote control stored on the channel 4 of
the receiver.
Mon
the relay is activated for all the length of the transmission of
the remote control. Releasing the key of the remote control the
relay is deactivated
tiM
the relay is activated receiving the transmission of the remote
control; it is disabled after the time set for the parameter
t.LUC
inside the menu
LUCi
biSt
the status of the relay changes at each transmission of
the remote control
Setting low voltage exit lights
This menu makes to possible to set the flashing exit function.
no
Not used
FLSh
Flasher operation (fixed frequency)
WL
Indicator light operation: Indicates the status of the gate in
real-time. The type of blinking indicates the four possible
conditions:
- GATE STOPPED: Light off
- GATE IN PAUSE: the light is on, fixed
- GATE OPENING: the light blinks slowly (2 Hz)
- GATE CLOSING: the light blinks quickly (4 Hz)
Blinker during pause time
Blinker usually operates during the gate motion only; however, if this
function is enabled, blinker will be on during the pause time too
(gate open with automatic closure active).
The flasher may be either in the device connected to the
LUCI
output
(setting the
CiCL
parameter in the
LUCi
menu) or the device connected
to the low voltage output (setting the
FLSh
parameter in the
SPiA
menu).