E
N
G
L
IS
H
64
DISPLAY
DATA
DESCRIPTION
DEFAULT
MEMO
DATA
dir
dx / Sx
Gate direction (the direction you see from the inside)
dx
En.SA
no / Si
ENERGY SAVING function
no
t.PrE
1.0" ÷ 1’.00
Advance blinking time
1.0”
no
- Advance blinking disabled (corresponds to a value of 0)
P.APP
0 ÷ 100
Partial opening
25
Pot
30 ÷ 100
Power motor
60
P.rAL
0 ÷ 70
Power motor during slow-down phase
20
P.bAt
no / Si
Maximum motor power during battery operation
no
SPUn
no / Si
Starting
no
rAM
6 ÷ 0
Advance rate
6
SEnS
no ÷ 10.0A
Obstacle sensor
no
rAPP
0 ÷ 100
Slow down in opening
10
rACh
0 ÷ 100
Slow down in closing
10
St.AP
Start during opening
PAUS
no
- The START command is ignored
ChiU
- The gate recloses
PAUS
- The gate pauses
St.Ch
Start during closure
StoP
Stop
- The gate completes the cycle
APEr
- The gate reopens
St.PA
Start during pause
ChiU
no
- The START command is ignored
ChiU
- The gate recloses
PAUS
- The pause time is restarted (Ch.AU)
SPAP
Pedestrian start during opening
PAUS
no
- The P. START command is ignored
ChiU
- The gate recloses
PAUS
- The gate pauses
Ch.AU
Automatic reclosure
no
no
- Automatic reclosure is not activated (corresponds to a value of 0)
0.5"÷ 20.0'
- The gate recloses after the set period time
Ch.tr
Closure after passage
no
no
- Closure after passage disabled (load Ch.AU)
0.5"÷ 20.0'
- The gate recloses after the set period time
PA.tr
no / Si
Pause after passage
no
LUCi
Courtesy lights
CiCL
t.LUC
- Timed function (from 0 to 20’)
no
- Function deactivated
CiCL
- On for the entire duration of the cycle
AUS
Auxiliary channel
Mon
tiM
- Timed function (from 0 to 20’)
biSt
- Bistable operation
Mon
- Monostable operation
13.2 - SUMMARY OF FUNCTIONS