ENGLISH
- 5 -
Lumos is an LED flasher unit for indicating the hazards associated
with the use of automation devoices for gates, garage doors and
road barriers; any other use is forbidden and inappropriate.
IMPORTANT WARNING
Warning! The installation of the product has to be made by
qualified personnel, under the laws and rules in force and
following the instructions of this handbook.
It is important to respect the following warnings:
• Check that the voltage of the product is compatible with the
one on the clamp of the control unit used for the connection
of the flashing light.
• Before making the electrical connections, cut electricity off the
control unit.
REFERENCE OF MARKING SYMBOLS:
The label affixed to the product bears the following symbols that
have the following meaning:
continuous current power supply voltage
protection against electric shock guaranteed by
reinforced
insulation
TECHNICAL FEATURES
Power supply
24 ÷ 300V
24 ÷ 230V~ 50/60Hz
Consumption
1,15W (230V - 5mA)
1,15W (115V - 10mA)
0,7W (24Vac - 30mA)
0,9W (30Vdc - 30mA)
Intermittence
automatic
Classe di isolamento
II
Protection degree
IP54
Working temperature
-20 ÷ +60 °C
Dimensions
136 x 82 x 35 mm (Fig. 1)
167 x 82 x 60 mm (Fig. 2)
PRELIMINARY CHECK
• Check the packaging integrity before opening it and, once
open, check the product integrity inside it
• Check that the place chosen for the installation grant the user
total visibility of the flashing light from a long distance
• Check that the surface chosen for the installation is strong
and grant a steady fixing
m
ATTENZIONE: WARNING: avoid the surfaces where
seepage in case of rain is possible
INSTALLATION
1.
To define the points envisaged for installation, bearing in mind
that it is necessary to fix the flashing unit onto a flat linear
surface and that the device may only be installed in a vertical
position (Fig. 1-2)
2.
Define the groove path for the electric cables
3.
Open the case of the flashing light and use the base
A
to mark
the fixing holes if the flashing light has to be installed on an
horizontal surface (Fig. 1); use the piece
B
if the flashing light
has to be installed on a vertical surface (Fig. 2)
4.
Fix the base and connect to the terminal board: connect the
flashing light output of the control unit on the GREEN terminal
of the flashing light
m
WARNING: use a cable suitable for external use with
a minimum section of 2x0,5 mm
2
and a maximum one of
2x1,5mm
2
5.
Connect the built-in antenna on the BLUE terminal.
Respect the silkscreen on the terminal.
m
WARNING: use a cable RG174
6.
Seal the holes of the plugs with silicone to avoid seepage of
water inside the device
7.
Close the box with the special screws
DISPOSAL
As for the installation, the disposal of the product at the end of its
effective life must be performed by qualified personnel.
This product is made of various types of material, some of which
can be recycled while others must be disposed of.
Enquire about the recycling or disposal systems available for this
product category in compliance with regulations locally in force.
EU DECLARATION OF CONFORMITY
V2 S.p.A. hereby declare that LUMOS equipment conforms to the
essential requirements established in directives:
2014/35/UE low voltage directive
2014/30/EU electromagnetic compatibility directive
RoHS2 2011/65/EC
Racconigi, 01/06/2015
Legal representative, V2 S.p.A.
Antonio Livio Costamagna