1 - IMPORTANT REMARKS
m
Prior to proceeding with installation, it is essential the
instructions be read in full, since they contain important
information regarding safety, installation, use and
maintenance.
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE WITH
THE EUROPEAN REGULATIONS IN FORCE:
EN 60204-1, EN 12453, EN 13241-1, EN 12635
• The installer must provide for a device (es. magnetotermical
switch) ensuring the omnipolar sectioning of the equipment
from the power supply. The standards require a separation of
the contacts of at least 3 mm in each pole (EN 60335-1).
• Installation requires mechanical and electrical skills, therefore it
shall be carried out by qualified personnel only, who can issue
the Compliance Certificate concerning the whole installation
(Machine Directive 2006/42/CE).
• It is mandatory to comply with standard EN 13241-1 and any
other national provisions.
• Also the automation upstream electric system shall
comply with the laws and rules in force and be carried out
workmanlike. V2 S.p.A. declines any responsibility in case of
automation upstream electric system not complying with the
laws and rules in force and not carried out workmanlike
• The gate’s thrust force and its sensitivity to obstacles shall
be measured using an appropriate tool and adjusted in
compliance with the maximum permitted values, provided in
standard EN 12453.
• This test and measurement of force may only be performed by
a professional. When hitting an obstacle the door has to stop
and reverse (completely or partially, depending on the setting
of the PCB).
If the gate does not slide on the requested path or if it
does not change its sliding direction as soon as it detects
an obstacle, you need to readjust the obstacle detection
sensitivity. Then please repeat the test.
If the door after the performed corrections does not stop and
reverse according to the valid norms, the door may not be
operated automatically.
• The use of AZIMUT in dusty, saline or explosive environment is
forbidden
• The opener is designed for operation in dry rooms exclusively
• For the safety and life of persons it is absolutely necessary to
follow all instructions.
• Keep these instructions save for later reference
• Do not permit children to play with the automated garage
door. Transmitters are to be kept safe and away from children!
• Only operate the door if the entire door area is in your field of
view. Always be sure, that no persons or objects are located
within traveling range of the door
• Do not use the opener when service or adjustment work
is required. A badly balanced door, or a faulty garage door
system may cause injuries.
• Please inform all persons using the door system on how to
operate it correctly and safely.
• Check often the automation, particularly the cables, springs
and mechanic parts for wear and tear, damages and
unbalancing.
• The plug must be at easy reach, after the installation.
• The data on the plate of the product are written on the label
put next to the connection terminal board.
• Any control devices installed in fixed locations (such as buttons
or similar devices) must be positioned within the field of view
of the gate, at a height of at least 1.5m from the ground.
It is essential that they are mounted out of reach of children!
• Affix warning signs indicating the risk of being caught in the
door where they may be seen immediately or in the vicinity of
the permanently mounted push button.
V2 has the right to modify the product without previous
notice; it also declines any responsibility to damage or
injury to people or things caused by improper use or wrong
installation.
Summary of Contents for 25B005
Page 2: ...105 mm 310 mm 170 mm...