ENGLISH
- 21 -
8 - ELECTRICAL CONNECTIONS
The control panel inside AZIMUT is already cabled.
You just need to plug it in the electrical outlet to proceed with
operational parameter programming.
9 - SETTING OF THE OPERATION
PARAMETERS
AZIMUT is equipped with a practical interface that allows rapid
and simple on-display programming using four keys:
,
,
+
,
-
Preliminary operations:
1.
Move the door so as to hook on the drive trolley.
2.
Power up the device: the courtesy light comes on, the
control unit emits a BEEP and the segments of the display are
illuminated one at a time until the display shows
0
.
m
PLEASE NOTE: The open limit switch must be stored prior to
the close limit switch. If this procedure is used erroneously to set
the close limit switch, the parameter is NOT stored
m
PLEASE NOTE: if programming is not completed (by
means of function 9.
End programming) the parameters set are lost.
If there is an error in the set parameters, simply power off
the device, restore power and then repeat the programming
operation.
+
-
+
-
+
-
+
-
+
-
Press the
key for
5 seconds
When the door reaches the
desired position, press the
key to save the settings
The device emits a beep
and the display shows
I
Press the
key:
I
flashes
Press and hold the
+
(the door opens)
or
-
(the door closes)
key to reach the fully open
position
9.1 - SETTING THE OPEN LIMIT SWITCH
ANT
Antenna
GND
Common (-)
IR1
Photocell 1. N.C. contact
IR2
Photocell 2. N.C. contact
IR.V+
+24Vdc supply for photocells
LAMP
Flashing light 24V
DOOR
START - Open command for
connecting traditional devices with
N.O. contact
GND
Common (-)
EMRG
STOP. N.C. Contact
LAMP
DOOR
GND
EMRG
-
+
IR.V+
IR2
IR1
GND
ANT