E
N
G
L
IS
H
56
Function of input Start
This menu allows choosing the mode of operation of the entries (see
paragraph Activation Entries):
StAn
Standard mode: first input command (START1) controls the
opening, the closing and the arrest depending on the
programming mode set.
no
The Start input commands on the terminal strip are disabled.
The radio command function depending of the mode
StAn
.
SLA
Modality SLAVE: in both the START commands are disabled.
The control unit is controlled from another control unit
(MASTER) connected to input commands SL-IN and SL-OUT (see
paragraph SYNCHRONIZED OPERATION OF TWO BARRIERS)
AP.CH
Open/Close mode: the impulse on command START1 always
commands the opening, on START2 always commands the
closing.
PrES
Man present mode: the barrier is opened until command START1
is active and it is closed until command START2 is active.
oroL
Clock Mode: operation with a timer; the barrier remains opened
as long as command START1 remains closed; at opening from
the contact it begins the counting of the pause time.
m
PLEASE NOTE: it is essential that automatic closure
be activated
Stop input
This menu allows selecting the functions associated to the STOP
command.
no
The input STOP is disabled.
It is not necessary to make a jumper connection the inputs
from the terminal strip with the common
ProS
The STOP command set the barrier idle: on the next successive
command START the barrier resumes the motion in the same
direction.
InvE
the STOP command sets the barrier idle: on the next successive
START command makes the barrier resume the motion in the
opposite direction to the previous one.
NOTE: during the pause the STOP command stops the counting of
the pause time, the next START command will always reclose the
barrier.
Photocell input
This menu allows programming the behavior in case of participation of
the photocell.
no
Disabled input (the control unit ignores it).
It is not necessary to make a jumper connection the inputs
from the terminal strip with the common
APCh
Input always enabled. The interruption of the photocell during
the opening or closing causes the arrest of the barrier.
At reset the barrier resumes the opening movement.
The interruption when in closed barrier inhibits the opening.
CFCh
Input enabled in closing and with closed barrier.
The interruption of the photocell during the closing causes the
reopening.
Ch
Input command enabled only in closing. The interruption of the
photocell during the closing causes the reopening
ATTENTION: if this option is chosen, it is necessary to
disable the test of photocells
Summary of Contents for 36A004
Page 2: ......
Page 9: ...ITALIANO 7 Fig 3...
Page 11: ...ITALIANO 9...
Page 16: ...ITALIANO 14...
Page 34: ...ITALIANO 32 INSTALLAZIONE DELL ACCESSORIO 163604...
Page 41: ...ENGLISH 39 Fig 3...
Page 43: ...ENGLISH 41...
Page 48: ...ENGLISH 46...
Page 66: ...ENGLISH 64 INSTALLATION OF THE ACCESSORY 163604...
Page 73: ...FRAN AIS 71 Fig 3...
Page 75: ...FRAN AIS 73...
Page 80: ...FRAN AIS 78...
Page 98: ...FRAN AIS 96 INSTALLATION DE L ACCESSOIRE 163604...
Page 105: ...ESPA OL 103 Fig 3...
Page 107: ...ESPA OL 105...
Page 112: ...ESPA OL 110...
Page 130: ...ESPA OL 128 INSTALACI N DEL ACCESORIO 163604...
Page 131: ......
Page 132: ......