4.5 - STOP
For a better safety, you can fit a stop switch that will cause the
immediate gate stop when activated. This switch must have a
normally close contact that will get open in case of operation.
In case the stop switch is operated while the gate is open, the
automatic closing function will always be disabled. To close the
gate again, you will need a start command.
Connect the stop switch cables between terminal
M3
and
M4
of
the control unit.
The STOP switch function can be activated by means of a remote
control stored on channel 3 of MR receiver
4.6 - PHOTOCELLS
The control unit considers two kinds of photocells, depending on
the terminal to which they are connected:
Photocell 1
Photocells installed on the gate inner side, which are active both
during the opening and the closing phase. When photocells 1
operate, the control unit stops the gate; as soon as the photocell
beam is free, the control unit will open the gate completely.
m
WARNING: Type 1 photocells must be installed so that
they completely cover the opening area of the gate.
Photocell 2
Photocells installed on the external gate side and which are active
during the closing phase only. When photocells 2 operate, the
control unit opens the gate immediately, without waiting for
release.
KB1 control unit supplies a 24 Vdc power supply to photocells and
it can perform a photocell operation test before starting the gate
opening phase. Photocell power terminals are protected by an
electronic fuse that stops current in case of overload.
• Connect power supply cables of photocells transmitter
between terminals
M11
and
M12
of the control unit.
• Connect power supply cables of photocells receiver between
terminals
M10
and
M11
of the control unit.
• Connect receiver output of photocells 1 between terminals
M5
and
M9
of the control unit and receiver output of photocells 2
between terminals
M6
and
M9
of the control unit.
Use outputs having normally closed contact.
m
ATTENZIONE
:
• If several couples of same kind photocells are mounted, their
outputs must be connected in series.
• In case of reflection photocells, power supply must be
connected to terminals
M11
and
M12
of the control unit to
carry out the operation test.
4.7 - SAFETY RIBBONS
The control unit considers two kinds of safety ribbons, depending
on the terminal to which they are connected:
Type 1
When type 1 safety ribbons operate during the gate opening
phase, the control unit will close the doors for 3 seconds, then it
stands still; when type 1 safety ribbons operate during the gate
closing phase, the control unit will stand still immediately.
The direction of the gate at next command of START or
PEDESTRIAN START depends upon the parameter STOP (it inverts
or continues the motion).
If the input STOP is disabled, the command makes the motion
continue in the same direction.
Type 2
when type 2 safety ribbons operate during the gate opening
phase, the control unit will stand still immediately; when type 2
safety ribbons operate during the gate closing, the control unit
will open the doors for 3 seconds, then it will stand still. The
direction of the gate at next command of START or PEDESTRIAN
START depends upon the parameter STOP (it inverts or continues
the motion). If the input STOP is disabled, the command makes
the motion continue in the same direction.
Both the input can manage the classic safety edge with n.c.
contact and the conductive rubber safety edge with 8,2 kohm
nominal resistance.
Connect type 1 safety ribbons cables between terminals
M7
and
M9
of the control unit.
Connect type 2 safety ribbons cables between terminals
M8
and
M9
of the control unit.
In order to meet the requirements of the EN12978 rules, it is
necessary to install safety edges controlled by a control unit
continuously checking the proper working. If using control units
suited to the test by power outage, connect the power supply
cables of the control unit between terminals
M11
and
M12
of the
control unit.
Otherwise, connect them between terminals
M10
and
M11
.
m
WARNING:
• Make use of safety ribbons having outputs with normally close
contact.
• Outputs of same kind safety ribbons must be connected in
series.
4.8 - EXTERNAL AERIAL
We suggest to use the external aerial (model: ANS433) in order to
guarantee the maximal range.
Connect the antenna hot pole to terminal
A2
of the control unit
and the braiding to terminal
A1
.
Summary of Contents for AYROS
Page 30: ...ITALIANO 28 ...
Page 32: ...ITALIANO 30 ...
Page 60: ...ENGLISH 58 ...
Page 62: ...ENGLISH 60 ...
Page 90: ...FRANÇAIS 88 ...
Page 92: ...FRANÇAIS 90 ...
Page 120: ...ESPAÑOL 118 ...
Page 122: ...ESPAÑOL 120 ...
Page 150: ... 148 PORTUGUÊS ...
Page 152: ... 150 PORTUGUÊS ...
Page 180: ...DEUTSCH 178 ...
Page 182: ...DEUTSCH 180 ...
Page 210: ...NEDERLANDS 208 ...
Page 212: ...NEDERLANDS 210 ...
Page 240: ... 238 POLSKI ...
Page 242: ...POLSKI ...
Page 243: ......