ENGLISH
- 50 -
13 - PROGRAMMING THE CONTROL UNIT
The configuration menu
-PrG
consists in a list of configurable
items; the display shows the selected item.
By pressing
i
, you will pass to the next item; by pressing
h
, you
will return to the previous item.
By pressing
OK
, you can view the current value of selected item
and possibly change it.
The last menu item (
FinE
) allows storing the carried out changes
and going back to the control unit normal operation.
You must exit from programming mode through this menu item if
you do not want to lose your configuration.
m
WARNING: in case no operation is carried out for more
than one minute, the control unit exits from the
programming mode without saving any of your setups and
changes, which will get lost.
By holding down the
i
or
h
keys, configuration menu items will
scroll fast, until item
FinE
is viewed.
In this way, you can quickly reach either the top or bottom of the
list.
P.APP
dir
FinE
-PrG
PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
dir
Gate direction (the direction you see from the inside)
dX
d
][
The gate opens rightwards
S
][
The gate opens leftwards
P.APP
Partial opening
25
0 - 1 00
The percentage of the path the gate performs in the case of opening
using the Pedestrian Start command
t .PrE
Pre-blinking time
1 .0”
0.5” - 1 ’00
Before any gate movement, blinker will be activated for
t.PrE
time, to
warn about the incoming motion (adjustable time from 0.5” to 1’00)
no
Function deactivated
t .PCh
Different closing pre-flashing time
no
0.5” - 1 ’00
If this parameter has a value assigned to it, the control unit will activate
pre-flashing prior to closure for the length of time set in this menu
(adjustable time from 0.5” to 1’00)
no
The closing pre-flashing time corresponds to
t.PrE
Pot
Motor power
80
35 - 1 00
The displayed value is the percentage of max. motor power
SPUn
Start off
Si
Si - no
If this function is activated, for the first 2 seconds of motion of each door,
the control unit will ignore
Pot
value and it will give motor the maximum
power command in order to overcome the gate inertia
rAM
Starting ramp
4
0 - 6
In order not to stress too much the motor, when the motion starts the
power is gradually increased, until reached the set value or 100% if the
take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is the
time necessary to reach the value of nominal power.
Summary of Contents for AYROS
Page 30: ...ITALIANO 28 ...
Page 32: ...ITALIANO 30 ...
Page 60: ...ENGLISH 58 ...
Page 62: ...ENGLISH 60 ...
Page 90: ...FRANÇAIS 88 ...
Page 92: ...FRANÇAIS 90 ...
Page 120: ...ESPAÑOL 118 ...
Page 122: ...ESPAÑOL 120 ...
Page 150: ... 148 PORTUGUÊS ...
Page 152: ... 150 PORTUGUÊS ...
Page 180: ...DEUTSCH 178 ...
Page 182: ...DEUTSCH 180 ...
Page 210: ...NEDERLANDS 208 ...
Page 212: ...NEDERLANDS 210 ...
Page 240: ... 238 POLSKI ...
Page 242: ...POLSKI ...
Page 243: ......