INSTALLATION MEASURES

To carry out a proper installation of the operator parts as well as
to ensure the best automation performance, the measurement
levels shown in the following table shall be complied with.
Change the gate structure to adapt it to one of the cases in the
table, if necessary. 

WARNING: In the case of leaf longer than 2 metres, 

an electric lock must be fitted to ensure an efficent closig.

CALYPSO 400

γ

A [mm]

B [mm]

C [mm]

F [mm]

90°

20

130

130

1010

40

150

140

1000

60

170

150

990

80

190

150

980

100

200

150

980

120

210

140

980

140

250

120

1010

100°

20

130

170

970

40

150

180

960

60

170

180

960

80

190

170

970

100

210

140

990

110°

20

130

190

950

40

150

180

960

50

160

170

970

CALYPSO 500

γ

A [mm]

B [mm]

C [mm]

F [mm]

90°

20

130

170

1200

40

150

180

1190

60

170

180

1190

80

190

190

1180

100

210

190

1170

120

230

190

1170

140

250

180

1170

160

270

190

1170

180

290

170

1180

100°

20

130

160

1210

40

150

170

1200

60

170

170

1200

80

200

180

1190

100

210

170

1190

120

230

190

1170

140

250

180

1180

160

270

160

1200

170

280

160

1200

110°

20

130

170

1200

40

150

180

1190

60

170

180

1190

80

190

190

1180

100

210

200

1170

110

220

200

1170

Summary of Contents for Calypso 400

Page 1: ...RSIBLE PARA CANCELAS BATIENTES ACTUADOR ELECTROMEC NICO IRREVERS VEL PARA PORT ES DE BATENTE NICHT UMKEHRBARER ELEKTROMECHANISCHER ANTRIEB F R FL GELTORE ELEKTROMECHANISCHE ONOMKEERBARE LINEAIRE MOTOR...

Page 2: ...hrust force adjustment shall be measured by means of a proper tool and adjusted according to the max limits which EN 12453 allows We recommend to make use of an emergency button to be installed by the...

Page 3: ...urrent A 1 1 2 2 Full load current A 1 4 1 4 2 8 2 8 Maximum Power W 300 300 300 300 Capacitor F 8 8 25 25 Max travel mm 400 500 400 500 Operating speed m s 0 016 0 016 0 018 0 018 Maximum thrust N 26...

Page 4: ...Y STEPS The new series of actuadors CALYPSO has been devised to serve gates up to 500 Kg with leaf up to 3 meters wide look at the table technical data Before proceeding with the installation please m...

Page 5: ...40 150 140 1000 60 170 150 990 80 190 150 980 100 200 150 980 120 210 140 980 140 250 120 1010 100 20 130 170 970 40 150 180 960 60 170 180 960 80 190 170 970 100 210 140 990 110 20 130 190 950 40 150...

Page 6: ...k the actuators Position CALYPSO on the brackets and fix the pins no 1 and no 2 with seeger see the picture Open and close the swings repeatedly manually to verify the absence of frictions between gat...

Page 7: ...ing open and close operations EMERGENCY RELEASE In case of a blackout the gate can be operated directly from the motor Insert the key supplied in the lock perform 1 2 of a turn To restore the automati...

Reviews: