E

N

G

L

IS

H

11

L1

START/UP. N.O. contact

L2

STOP. N.C. contact

L3

COMMON (-)

L4

DOWN. N.O. contact

L5

PHOTOCELL. N.C. contact

L6

EDGE. N.C. contact
(Safety edge - parameter 

in5

oFF

)

FCA. N.C. contact
(Opening limit switch - parameter 

in5

on

)

L7

FIRE. N.C. contact
(Alarm - parameter 

in5

oFF

)

FCC. N.C. contact
(Closing limit switch - parameter 

in5

on

)

L8

COMMON (-)

L9

Adjustment of the power for OPTICAL SAFETY EDGE

L10

30 Vdc power output for photocells and
other accessories

L11

30 Vdc power supply for functional test
TX photocell

E1 - E2

Flashing light 230Vac / 120Vac 
(parameter 

ou1

oFF

)

Courtesy light 230Vac / 120Vac
(parameter 

ou1

on

)

E3

Motor open

E4

Motor common

E5

Motor close

N

230Vac / 120Vac power supply - neutral

L

230Vac / 120Vac power supply - phase

A1

Antenna shield

A2

Antenna 

OPTICAL EDGE INSTALLATION

The EASY-TOP main control unit is configured for the installation
of one 24 Vdc powered optical edge and transmitter power
regulation.

Connect the transmitter and receiver in accordance
with the following table.

After having made the connections, power-up the main control
unit and adjust the power using the trimmer TR1 located on the
control unit so as to obtain optimal edge operation.

FIRE / ALLARM INPUT

Safety input for connecting a fire or other type of alarm requiring
the immediate automatic opening of the door.

The FIRE command should be connected between the FIRE (L7)
and COMMON (L8) terminals.

When the FIRE contact is opened, the door is opened and cannot
be closed again until the contact is reset.

NOTE: If the input is set as an alarm (

in4

oFF

), when the FIRE

contact is open, the port cannot be opened. If the port is already
open, it is closed.

PLUG IN RECEIVER

The control unit is suitable for plugging in a MR receiver.

MR module receiver is provided with 4 channels and each of
them is suitable for a command of the control unit:
• CHANNEL 1 

g

START/UP

• CHANNEL 2 

g

STOP

• CHANNEL 3 

g

DOWN

• CHANNEL 4 

g

COURTESY LIGHT

m

WARNING: Before programming 4 channels and

function logics read carefully the instructions of MR

TRANSMITTER

RECEIVER

L6

BLACK CABLE

L8

BLUE CABLE

BLUE CABLE

L9

BLACK CABLE

L10

BROWN CABLE

L11

BROWN CABLE

Summary of Contents for EASY-TOP

Page 1: ...v2home com www v2home com CENTRALE DI COMANDO DITALE PER SERRANDE AVVOLGIBILI DIGITAL CONTROL UNIT FOR ROLLER SHUTTERS ARMOIRE DE COMMANDE DIGITALE POUR STORES CUADRO DE MANIOBRAS DIGITAL PARA PERSIAN...

Page 2: ...rules EN 12453 EN 12445 EN 12978 as well as any local rule in force Also the automation upstream electric system shall comply with the laws and rules in force and be carried out workmanlike The door t...

Page 3: ...ENGLISH 10 ELECTRIC CONNECTIONS mWARNING Normally closed inputs STOP L2 PHOTOCELL L5 EDGE L6 FIRE L7 if not used must be bridged through the COMMON terminal L3 L8...

Page 4: ...ordance with the following table After having made the connections power up the main control unit and adjust the power using the trimmer TR1 located on the control unit so as to obtain optimal edge op...

Page 5: ...5B025 which besides using the keypad allows controlling the edges by radio using the special sensors see the WES EASY instructions The keypad buttons operate in parallel with the terminal controls The...

Page 6: ...SEL keys To access the programming menu press the MENU key until the display shows in 1 To change the value of this parameter press the MENU key the display shows the currently set value on oFF Selec...

Page 7: ...L6 input is configured to manage an opening limit switch The L6 input is configured to manage a closing limit switch NOTE If in 5 is set on the settings of the in 3 and in 4 functions they are not con...

Page 8: ...tive safety keep the command active for 5 seconds the control unit then activates dead man mode and the shutter moves as long as the switch is held When the command is suspended the control unit retur...

Reviews: