EU DECLARATION OF CONFORMITY
AND DECLARATION OF 
INCORPORATION OF PARTLY 
COMPLETED MACHINE

Declaration in accordance with Directives: 2014/35/UE (LVD);
2014/30/UE (EMC); 2006/42/CE (MD) ANNEX II, PART B

The manufacturer V2 S.p.A., headquarters in 
Corso Principi di Piemonte 65, 12035, Racconigi (CN), Italy 

Under its sole responsibility hereby declares that:
the partly completed machinery model(s): 
LEX-KNX20-230V, LEX-KNX40-230V, LEX-KNX50-230V

Description: electromechanical actuator for awnings and 
rolling shutters

•  is intended to be installed on awnings and rolling shutters
  to create a machine according to the provisions of the 
  Directive 2006/42/EC. The machinery must not be put into 
  service until the final machinery into which it has to be 
  incorporated has been declared in conformity with the 
  provisions of the Directive 2006/42/EC (annex II-A).
•  is compliant with the applicable essential safety requirements 
  of the following Directives:
  Machinery Directive 2006/42/EC (annex I, chapter 1) 
  Low Voltage Directive 2014/35/EU 
  Electromagnetic Compatibility Directive 2014/30/EU 
  Radio Directive 2014/53/EU
  Directive ROHS2 2011/65/CE

The relevant technical documentation is available at the national 
authorities’ request after justifiable request to:
V2 S.p.A., Corso Principi di Piemonte 65, 
12035, Racconigi (CN), Italy

The person empowered to draw up the declaration and to provide 
the technical documentation:

Giuseppe Pezzetto

Legal representative of V2 S.p.A.
Racconigi, 30/01/2018

m

 IMPORTANT REMARKS

•  Please read the instruction carefully before installation
•  Follow all instructions, since incorrect installation can lead to 

severe injury

•  The installation must be done by a technician following the 

safety norms in force

•  Only apply to authorized personnel to replace the feeding 

cable of the motor

•  Do not pierce nor insert screws in the whole length of the 

motor

•  Avoid any contact of the motor with liquids
•  Avoid to crush or knock over the motor
•  Possible tampering or wrong connections are not covered by 

guarantee

  If a manual release is provided, the actuating member is to be 

installed at a height less than 1,8m

  Before installing the drive, remove any unnecessary cords and 

disable any equipment not needed for powered operation.

  For installation for awnings, a horizontal distance of at least 

0,4 m is to be maintained between the fully unrolled driven 
part and any permanent object

  The power supply cable should not be exposed to sunlight or 

rain directly

  Assure that all accessories have been fixed so that the motor 

works without any mechanical problem. The loading weight 
should be matched with the output power of the motor

  Electrical connection must be done by professional technicians 

to operate in conformity with the rules

•  Do not allow children to play with fixed controls
•  Keeps remote controls away from children
•  Frequently examine the installation for imbalance and sings of 

wear or damage to cables and springs

•  Do not use if repair or adjustment is necessary
•  Moving parts of the drive must be installed higher than 2.5 m 

above the floor or other level that could provide access to it

•  The actuating member of a biased-off switch is to be located 

within direct sight of the driven part but away from moving 
parts. It is to be installed at a minimum height of 1.5 m

•  Fixed controls have to be installed visibly
•  The appliance can not be used in outside

 

TECHNICAL ASSISTANCE SERVICE

For any installation problem please contact our Customer Service 
at the 39-0172.812411 operating Monday to Friday
from 8:30 to 12:30 and from 14:00 to 18:00.

Summary of Contents for LEX-KNX Series

Page 1: ...FACCIA KNX MANUALE PER L INSTALLAZIONE GB TUBULAR GEARMOTOR Ø 45 MM WITH KNX INTERFACE INSTALLATION MANUAL F MOTOREDUCTEUR TUBULAIRE Ø 45 MM AVEC INTERFACE KNX MANUEL POUR L INSTALLATION D ROHRMOTOR Ø 45 MM MIT SCHNITTSTELLE KNX HANDBUCH FÜR DIE INSTALLATION LEX KNX ...

Page 2: ... 2 Fig 1 Fig 2 SW1 Fig 4 ...

Page 3: ...cità alimentazione potenza tempo di funzionamento lunghezza L Model load torque speed power supply power working time length L Kg Nm rpm V Hz W min mm LEX KNX20 230V 35 20 15 230 50 145 4 550 LEX KNX40 230V 80 40 15 230 50 198 4 600 LEX KNX50 230V 95 50 12 230 50 205 4 600 17 33 L 52 M4 4 8 59 Ø45 ...

Page 4: ... Erde 4 NERO Pulsante esterno BLACK External button NOIR Bouton externe SCHWARZ Externe Taste 5 BIANCO Pulsante esterno comune WHITE External button common BLANC Bouton externe commun WEISS Externe Taste Gemein 6 NERO dati KNX BLACK KNX data NOIR données KNX SCHWARZ Daten KNX 7 ROSSO dati KNX RED KNX data ROUGE données KNX ROT Daten KNX m ATTENZIONE NON COLLEGARE ALLA LINEA 230V ATTENTION DO NOT C...

Page 5: ...ollowing the safety norms in force Only apply to authorized personnel to replace the feeding cable of the motor Do not pierce nor insert screws in the whole length of the motor Avoid any contact of the motor with liquids Avoid to crush or knock over the motor Possible tampering or wrong connections are not covered by guarantee If a manual release is provided the actuating member is to be installed...

Page 6: ...witch within 5 seconds from fast flashing starts keep the button pressed to bring the roller shutter to the desired position To invert the movement direction release and press the button again 9 Having completed this setting wait 5 seconds until the led switches off and the motor moves in the two directions to confirm the new parameters were saved INSTALLATION FIG 1 2 Fasten the bracket G to the w...

Reviews: