ENGLISH
This type of programming allows loading the V2
ELETTRONICA default program in the memory: the
standard data that will be inserted automatically are
shown in the table below (in the column DEFAULT
DATA on pag. 43).
Set the wished function pressing the up or DOWN
keys and press MENU key to confirm.
GATE 1 OPENING TIME
This menu is adjustable from 0 to 120 seconds
(±0,5) and determines the time of opening of
gate 1.
GATE 2 OPENING TIME
This menu is adjustable from 0 to 120 seconds
(±0,5) and determines the time of opening of
gate 2.
OPENING TIME OF PEDESTRIAN GATE
This menu is adjustable from 0 seconds to t.AP1
(±0,5) and determines the opening time of
pedestrian gate.