32 - TERMINAL BOARD CONNECTIONS (FROM Fig.68 TO 73)
Connect all the components of the automatic door to the control unit with the appropriately sectioned electrical cables, in compliance with
the instructions in the following table:
N
REFERENCE
DEFAULT
DESCRIPTION
FIGURE
1
START1
NO
External sensor for opening command
Fig.68
2
COM
Common for inputs 1-5
3
OPTOREF
Not used (bridged)
4
-OO-
Not used (bridged)
5
START2
NO
Internal sensor for opening command
6
OUT 15VDC
(-)
Negative power supply for opening command sensors:
15Vdc - max. 0.25A
7
OUT 15VDC
(+)
Positive power supply for opening command sensors:
15Vdc - max. 0.25A
8
TEST CLOSE
(-)
Negative test circuit of the opening command sensor
Fig.69
9
TEST CLOSE
(+)
Positive test circuit of the opening command sensor
10
COM
Common signal for inputs 12-13
11
PHOTO COM
Not used
12
SAFE CLOSE 1
NC
Active external presence sensor (zone A2)
13
SAFE CLOSE 2
NC
Active external presence sensor (zone A1)
14
TEST OPEN
(-)
Negative test circuit of side opening safety sensors
Fig.70
15
TEST OPEN
(+)
Positive test circuit of side opening safety sensors
16
COM
Common signal for inputs 17-18 (bridged)
17
SAFE OPEN 1
NC
Right side opening safety sensor - zone A3 (bridged)
18
SAFE OPEN 2
NC
Left side opening safety sensor - zone A4 (bridged)
19
OUT 15VDC
(-)
Positive power supply on safety sensors in side opening:
15Vdc - max. 0.25A
20
OUT 15VDC
(+)
Negative power supply on safety sensors in side opening:
15Vdc - max. 0.25A
21
OUT 15VDC
(-)
Negative peripheral power supply:
15Vdc - max. 0.25A
Fig.71
22
OUT 15VDC
COM
(+)
Positive peripheral power supply:
15Vdc - max. 0.25A; additional common signal
23
KEY
NC
Night closure command
24
AUX OUT
Auxiliary output
-
25
AUX IN 1
Auxiliary input
-
26
AUX IN 2
Auxiliary input
-
27
LOCK
(+)
Electric lock
Fig.72
28
LOCK
L
Electric lock
29
-
(-)
Not used
-
30
GND
Logical selector GND cable
Fig.73
31
DATA
Logical selector DATA cable
32
PWF
Logical selector PWF cable
33
RST
Logical selector RST cable
34
AUX SEL
Auxiliary output
-
m
DANGER: comply with the connections in the table, comply with the polarities where necessary, do not connect the
utilities with absorptions over the limits in the table. The unit already has a series of bridged terminals (indicated in the table).
If these inputs are used for connection of the sensors, you need to remove the bridges.
On the contrary, an important safety function and movement of the doors could be compromised and could cause serious
damage to property and people with the risk of fatal injuries