8 - CONTROL UNIT
PD11 is provided with a display that, not only makes
programming simple, but also allows a continuous monitoring
of the input statuses; in addition, thanks to a menu structure,
the working schedule and the operation logic can be set easily.
In compliance with the European standards concerning
electrical safety and electromagnetic compatibility
(EN 60335-1, EN 50081-1 and EN 50082-1) it has been
equipped with the low voltage circuit total electric insulation
(motors included) from the network voltage.
Other characteristics:
• Automatic control for the null current relay switch.
• Power adjustment with wave shutting.
• Obstacle detection by means of monitoring start condenser
voltage.
• Automatic learning of the operation time.
• Specific entrances for end stops.
• Tests for safety devices (photocells, ribbons and triacs)
before each opening.
• Deactivation of safety inputs through the configuration
menu: no jumper is required for terminals concerning safety
devices that have not been installed, yet. You will only need
to disable this function from its relevant menu.
• Control unit programming can be locked through the optional
CL1+ key
m
WARNING: Installation of control unit and safety
devices must be carried out with power disconnected
8.1 - POWER SUPPLY
The control unit must be fed by a 230V 50Hz (120V - 50/60Hz
for the model PD11-120V) electric line, protected by a
differential magnetothermal switch complying with the law
provisions in force.
Connect power supply cables to terminals
L
and
N
of PD11
control unit
8.2 - COURTESY LIGHTS
Thanks to the output COURTESY LIGHT the control unit PD11
allows the connection of an electric appliance (e.g. courtesy
light or garden lights), controlled automatically or by means of
the special transmitter key.
The output COURTESY LIGHT is a simple N.O. contact with no
power supply.
Connect the cables to terminals
B1
and
B2
.
8.3 - WARNING LIGHT
Thanks to the WARNING LIGHT output, the PD11 central unit
allows you to monitor the state of the door in real time and the
kind of flashing signal indicates the four possible conditions:
STOP light off
IN PAUSE light always on
OPENING the light flashes slowly (2 Hz)
CLOSING the light flashes rapidly (4 Hz)
The output provides the connection of a 24V bulb. The
maximum charge shall be included in the 3W at the disposal
for the accessories.
Connect the cables to terminals
J7
and
J9
8.4 - PHOTOCELL
PD11 control unit supplies a 24VAC power supply to photocells
and it can perform a photocell operation test before starting
the door opening phase. Photocell power terminals are
protected by an electronic fuse that stops current in case of
overload.
The photocells are active only during the closing phase and, if
required, with standstill door. In case intervention, the control
unit immediately opens the door, not waiting for the release.
• Connect power supply cables of photocells transmitter
between terminals
J7
and
J8
of the control unit.
• Connect power supply cables of photocells receiver between
terminals
J6
and
J7
of the control unit.
• Connect receiver output between terminals
J4
and
J5
of the
control unit. Use outputs having normally closed contact.
m
WARNING:
• if several couples of photocells are mounted, their outputs
must be connected in series.
• In case of reflection photocells, power supply must be
connected to terminals
J7
and
J8
of the control unit to
carry out the operation test.