ENG
LISH
45
To carry out a proper installation of the operator parts as well as
to ensure the best automation performance, the measurement
levels shown in the following table shall be complied with.
Change the gate structure to adapt it to one of the cases in the
table, if necessary.
1.
Depending on the opening angle of the leaves or panels,
make sure it is possible to respect the dimensions reported in
the table
2.
Measure the value of
B
on-site
3.
Based on the value for dimension
B
and the opening angle of
the leaves or panels, the value of
A
may be deduced from the
table
PLEASE NOTE: the maximum permitted value for
dimension C is 650 mm. A greater value might result in
malfunctioning and consequent damage to the motor
B
A
90°
0 ÷ 60
120
60 ÷ 150
130
150 ÷ 180
140
180 ÷ 210
150
210 ÷ 230
160
230 ÷ 250
170
B
A
110°
0 ÷ 20
210
20 ÷ 30
220
30 ÷ 40
230
50 ÷ 60
240
60 ÷ 70
250
70 ÷ 80
260
80 ÷ 90
270
90 ÷ 110
280
B
A
100°
0 ÷ 50
150
50 ÷ 100
160
100 ÷ 130
170
130 ÷ 150
180
150 ÷ 170
190
170 ÷ 200
200
PLEASE NOTE: ensure there are no
obstacles near the motor that might
interfere with the arm, both during
movement and with the gate open.
Summary of Contents for ZARISS-M
Page 2: ......
Page 14: ...ENGLISH 52 Phase power supply 230Vac Earth Neutral power supply 230Vac ...