background image

 

Desktop UPS         

Line Interactive UPS 

                                     

UP S1P 600 E   

  This UPS utilizes voltage that may be hazardous. Do not 

attempt to disassemble the unit. The unit contains no user 
replaceable parts. Only factory-authorized service personnel 
may perform repairs. 

  Install the UPS close to an easily accessible power source. 

  Note: During the installation of this equipment the sum current 

leakage of the UPS and connected loads does not exceed 
3.5mA. 

  Connection to any other type of receptacle other than a 

two-pole, three-wire grounded receptacle may result in shock 
hazard and violate local electrical codes. 

  In the event of an emergency to properly disable the UPS, 

press the "OFF" button and disconnect the power cord from the 
AC power supply   

  Do not place beverages or liquids on or near the unit. Do not 

allow foreign objects to contact the ports of sockets of the UPS.     

  This unit intended for installation in a controlled environment 

(temperature-controlled indoor area free of conductive 
contaminants). Avoid installing the UPS in locations where 
there is standing or running water, or excessive humidity. 

  Do not plug the UPS input into any of its output sockets. 

  Do not attach a power strip or surge suppressor to the UPS. 

  Do not attach non-computer-related items, such as medical 

equipment, life-support equipment, microwave ovens, or 
vacuum cleaners to UPS. 

  Never incinerate depleted batteries as they may explode. 

 

MODEL 

600 

CAPACITY 

600VA/360W 

Input Voltage 

220/230/240 VAC 

Input Voltage Range 

162-290 VAC 

Output Voltage   
Regulation   

± 10 % (Bat. mode) 

Transfer Time   

Typical 2-6 ms 

Waveform 

Simulated Sine Wave 

Battery Type & No 

12V/7Ahx1 

Charging Time 

6 hours recover to 90% capacity 

Dimension (DxWxH) 

300 x 101 x 142 mm 

Net Weight (kgs) 

4.4 

Humidity 

0-90% RH @ 0-40°C non-condensing) 

Noise Level 

Less than 40dB 

*Specifications are subject to change without notice. 

  A battery can present a risk of electrical shock and high short 

circuit current. The following precautions should be observed 
when working on batteries: 

1) Remove watches, rings, or other metal objects from the hands. 
2) Use tools with insulated handles. 
3) Wear rubber gloves and boots. 
4) Do not lay tools or metal parts on top of batteries. 
5) Disconnect charging source prior to connecting or 

disconnecting batteries terminal. 

6) 

Determine if battery is inadvertently grounded. If inadvertently 

grounded, remove source from ground. Contact with any part 
of a grounded battery can result in electrical shock. The 

likelihood of such shock can be reduced if such grounds are 
removed during installation and maintenance.

 

  Internal battery is a voltage is a sealed, lead-acid, 6-cell battery. 

12VDC. 

  Servicing of batteries should be performed or supervised by 

personnel knowledgeable of batteries and the required 
precautions. Keep unauthorized personnel away from batteries. 

  When replacing batteries, replace with the same number and 

type of sealed lead-acid battery. 

  Do not open or mutilate the battery or batteries. Released 

electrolytes may be toxic are harmful to the skin and eyes. 

 

ATTENTION:

 Risk of electric shock, Hazardous voltage may 

still be present through the battery, even after disconnection of 
from the main power source. Before servicing, the battery 
supply should be disconnected from plus and minus poles at 
the on the battery connectors inside the UPS. 

  To reduce the risk of overheating, do not block or cover the 

UPS

’ cooling vent. Avoid exposing the unit to direct sunlight or 

installing the unit near heat emitting appliances such as space 
heater or furnaces. 

  Unplug the UPS prior to cleaning. Avoid using liquids or 

soaking wet cloth 

 

WARNING: This is a category C2 UPS product. In a residential 
environment, this product may cause radio interference, in 

which case the user may be required to take additional 
measures.

 

 

Problem 

Possible Cause 

Solutions 

Nothing is 
displayed on 
LCD panel. 

The UPS is not on. 

Press the power switch 
again to turn on the UPS. 

Battery  voltage  is  too 
low. 

Charge the battery at least   
6 hours. 

Battery fault. 

Replace the battery. 

The UPS 
always on 
battery mode. 

Check for a loose 
power cord. 

Firmly plug in the power 
cord. 

The UPS 
beeps 
continuously   

Check the fault code 

for the details. 

Check the fault code for the 
details 

Backup time 
too short. 

Battery voltage is too 
low. 

Charge the battery at least   
6 hours. 

Overload. 

Remove unnecessary loads. 
Before reconnecting 
equipment, please verify 
that the load matches the 
UPS power output 
specifications.   

Battery won

’t charge    Replace the battery. 

 

If any abnormal situations occur that are not listed above, please 
call for service immediately.

SAFETY CAUTION 

SAVE THESE INSTRUCTION - This manual contains important instructions that should be followed 

during installation and maintenance of the UPS and batteries. 

SPECIFICATIONS 

TROUBLESHOOTING 

Summary of Contents for CA08356

Page 1: ...p www v7world com us downloads to your hard drive Follow on screen instructions to complete the software installation Operation Display UPS Mode LCD Description UPS Power on When UPS is powered on it...

Page 2: ...ttery is inadvertently grounded If inadvertently grounded remove source from ground Contact with any part of a grounded battery can result in electrical shock The likelihood of such shock can be reduc...

Page 3: ...www v7world com us downloads auf Ihre Festplatte herunter Befolgen Sie dieAnweisungen auf dem Bildschirm um die Software zu installieren Betriebsanzeige USV Modus LCD Beschreibung USV eingeschaltet We...

Page 4: ...rdet ist Falls er versehentlich geerdet ist entfernen Sie die Quelle von der Erdung Der Kontakt mit einem Teil eines geerdeten Akkus kann zu einem Stromschlag f hren Die Wahrscheinlichkeit eines Strom...

Page 5: ...wnloads Siga las instrucciones de la pantalla para completar la instalaci n del software Pantalla operativa Modo del SAI LCD Descripci n Encendido del SAI Cuando se enciende el SAI entra en este modo...

Page 6: ...ier parte de una bater a conectada a tierra puede producir una descarga el ctrica La probabilidad de que se produzca una descarga de ese tipo se puede reducir si se desconecta la bater a de la tierra...

Page 7: ...s partir de http www v7world com us downloads Suivez les instructions affich es l cran pour terminer l installation du logiciel Affichage du fonctionnement Mode onduleur LCD Description Onduleur allum...

Page 8: ...retirez la source du sol Tout contact avec une partie quelconque d une batterie mise la terre peut entra ner une lectrocution La probabilit d une telle lectrocution peut tre r duite si ces motifs sont...

Page 9: ...ownloads Seguire le istruzioni sullo schermo per completare l installazione del software Display in funzione Modalit UPS LCD Descrizione UPS acceso Quando l UPS viene acceso entra in questa modalit pe...

Page 10: ...fonte dalla terra Il contatto con qualsiasi parte di una batteria messa a terra pu provocare elettrocuzioni possibile ridurre le probabilit di scariche rimuovendo la messa a terra durante l installaz...