For your convenience to understand this manual, use the product, and prevent personal injuries and goods damages, 
please read the following instructions thoroughly. 
Warning 
Please use a power socket with a ground wire to prevent electric shock.     
If the power socket is not grounded, the grounding wire must be installed by professional technicians. 
Be sure to place the Pharmacy Refrigerator firmly on a solid and flat ground. If the ground is not stable or the place 
is not suitable, the Pharmacy Refrigerator might be overturned or people will be injured. 
If the power cord needs to be lengthened, the sectional area of the lengthened cord shall not be less than 2.5m². 
At the same time, the length is not longer than 3 m. Otherwise, it may cause a fire or electric shock. 
In  case  of  flammable  gas  leakage,  it  is  necessary  to  close  the  gas  leakage  valve  and  open  doors/windows,  for 
ventilation.  Do  not  open  any  electrical  switch,  and  do  not  plug  in  or  pull  out  the  power  plug  of  the  Pharmacy 
Refrigerator, otherwise it may cause explosions and fires. 
Only  professional  technicians  or  after-sales  maintenance  personnel  can  disassemble  the  Pharmacy  Refrigerator, 
otherwise it may cause fires or electric shock. 
Please use the special power supply indicated on the nameplate of the Pharmacy Refrigerator, otherwise it may 
cause fire or electric shock. 
If the voltage is lower than 207V or higher than 253V is necessary to install more than 4000 W automatic voltage 
regulator suitable for motor load. 
The  power  cord  of  this  Pharmacy  Refrigerator  is  equipped  with  a  three-wire  (grounded)  plug,  which  meets  the 
standard three-wire (grounded) socket of 10 A. 
Under no circumstances should the grounding pin of the power cord be removed. Make sure that the power plug 
and socket are plugged firmly and reliably, otherwise it may lead to fires. 
When unplugging from the power socket, hold the power plug firmly and remove it. Do not pull the wires of the 
power plug directly. If you pull the wire by hand, it may cause electric shock or fires due to short circuit. 
If the Pharmacy Refrigerator is not working properly, please unplug the power plug. It may cause electric shock or 
fires if it continues to operate under abnormal conditions. 
Before  any  repair  or  maintenance  of  the  Pharmacy  Refrigerator,  always  disconnect  the  power  supply  of  the 
Pharmacy Refrigerator to prevent electric shock or personal injuries. 
Make sure that the medicine or suspended particles inside and around the Pharmacy Refrigerator will not be inhaled 
during maintenance, otherwise it may be harmful to health. 
When storing toxic, harmful, or radioactive materials, please use a Pharmacy Refrigerator in a safe area. Improper 
use may cause harm to human health or the environment. 
When  the  Pharmacy  Refrigerator  is  not  used  for  a  long  time,  unplug  the  power  plug  to  prevent  electric  shock, 
leakage or fires caused by the aging power cord. 
If  the  Pharmacy  Refrigerator  is  idle  for  a  long  time  in  an  unsupervised  area,  make  sure  that  the  child  does  not 
approach the Pharmacy Refrigerator and that the disposal of the Pharmacy Refrigerator is to be carried out by the 
appropriate personnel. The door should be removed to prevent accidents such as suffocation. 
No  flammable,  explosive,  dangerous  or  volatile  stuff  should  be  stored  in  Pharmacy  Refrigerator.  Do  not  use 
combustible sprays near the Pharmacy Refrigerator, otherwise it may cause explosions or fires. 
Do  not  store  corrosive  stuff  such  as  acids  and  alkalis  in  the  Pharmacy  Refrigerator.  Otherwise,  the  internal 
components or electrical parts of the Pharmacy Refrigerator may be damaged. 
Packaging  plastic  bags  should  not  be  placed  where  children  can  reach  them,  because  plastic  bags  may  cause 
suffocation. 

Summary of Contents for VS50

Page 1: ...keep it for future reference The design and speci cations are subject to change without prior notice for product improvement Consult with your dealer or manufacturer for details PHARMACY REFRIGERATOR...

Page 2: ...ries 6 3 PRODUCT OVERVIEW 7 4 TECHNICAL SPEC 7 5 OPERATION 8 5 1 Opera on and display panel 8 5 2 Key opera on 9 5 3 Noise Inside the Unit 13 5 4 ALARM 13 6 CLEANING 14 6 1 Cleaning the Interior and t...

Page 3: ...building in clear of obstruction WARNING Do not use mechanical devices or other means to accelerate the defrosting process other than those recommended by the manufacturer WARNING Do not damage the r...

Page 4: ...r more must be used and copper core conductors in the wall connected to the power socket must also have a cross sectional area of 4mm2 or more This series of products are strictly prohibited to put in...

Page 5: ...socket are plugged firmly and reliably otherwise it may lead to fires When unplugging from the power socket hold the power plug firmly and remove it Do not pull the wires of the power plug directly If...

Page 6: ...he insulation and cause leakage or electric shock Do not insert metal objects such as nails or wires into any openings and gaps of the Pharmacy Refrigerator or into any vent used for internal air circ...

Page 7: ...at both sides 15 cm at the rear and 20 cm at the top of the unit This will allow cold air to circulate around the Pharmacy Refrigerator and improve the efficiency of the cooling process The Pharmacy R...

Page 8: ...to the operation instructions below for details 4 Set parameter of cabinet temperature high low temperature alarm deviation etc according to actual need Default temperature setting is 5 C high temper...

Page 9: ...Model number VS50 External dimensions W D H mm 485 450 550 Effective volume 42L Door body Transparent glass door Foaming agent Cyclopentane Cooling mode Air cooling circulation Shell plate Inner Plat...

Page 10: ...on Button Locked off Button unlocked Power failure on Power off off Power on Printer disabled on Printer working off Printer not working Door heat disabled on Door heat working off Door heat not worki...

Page 11: ...locked if there is no operation for 60s or Up key and Down key are pressed for 3s at the same time b When the key is locked only ambient temperature can be checked and Mute key and Light switch key c...

Page 12: ...Lower deviation on low temperature alarm 0 0 10 0 0 cancel the alarm 3 n Check the current date year y Check the current date month r Check the current date day S Check the current date hour F Check t...

Page 13: ...o 1 Every time the door is opened and closed it will be heated for T9 minutes If the door is opened and closed again during the heating period the heating time will be reset Door heating mode P1 is se...

Page 14: ...eps once the digital tube displays the upload data code on in case of large amount of data and the USB flash disk generates the PDF files on data of current month and last month After the completion o...

Page 15: ...bient temperature alarm value tH1 sensor is normal and not shielded then the buzzer will alarm and the digital tube will flash the high ambient alarm code H2 alternately at the interval of 3 seconds e...

Page 16: ...fied technician for assistance 7 MAINTENANCE 7 1 Care When Handling Moving Your Unit Hold the unit around its sides or base when moving it Under no circumstances should it be lifted by holding the edg...

Page 17: ...t heat during operation specially in summer this is caused by the radiation of the condenser and it is a normal phenomenon Condensation condensation phenomenon will be detected on the exterior surface...

Page 18: ...16 REQUESTING ASSISTANCE OR SERVICE If you have any doubt or extra assistance please call Customer Service Vacc Safe Telephone 1300 459 140...

Reviews: