background image

12

Air Filter Maintenance

This machine has an air filter that should be changed every year and a

half, unless there is some type of upset condition, ie overfill of the pump

with oil, large amount of liquid getting into the chamber and into the

pump, etc...

To Change the Air Filter:

1. 

Remove back cover from machine and locate the air filter housing 

on the pump (see “Figure 1” below)

2.  Remove the 4 corner screws from end cap.
3. 

Catch the gasket and spring from behind the end cap.

4. 

Remove the old filter from housing.

5. 

Insert new filter into housing.

6. 

Replace the spring and gasket, making sure the gasket is still in 

good condition.

7. 

Re-attach the end cap with the 4 screws.

8. 

Filter re-assembly is complete.

How to Use

VP

400

 Chamber Vacuum Sealer | 

User Guide

ARY, Inc.  |  11880 College Blvd Suite 550 Overland Park, KS 66210 |  www.VacMasterFresh.com  |  800-821-7849

Summary of Contents for VP400

Page 1: ...v2018 08 20 v2018 08 20 P400 V 00 VP P400 V 00 VP VP400 USER GUIDE Chamber Vacuum Sealer...

Page 2: ...ign for increased production and speedy operation 4 inch smooth rolling casters allow the VacMaster VP400 Double Chamber Vacuum Sealer to be moved easily The VP400 base is constructed of stainless ste...

Page 3: ...Turn off and unplug machine to prevent electrocution 1 Using VacMaster approved 10W non detergent hydraulic oil fill the enclosed plastic oil bottle 2 Locate the oil fill bolt A on the top of the vac...

Page 4: ...rate any appliance with a damaged supply cord or plug or after the appliance malfunctions or has been dropped or damaged in any manner Supply cord replacement and repairs must be conducted by the manu...

Page 5: ...by the vacuum Use VacMaster Bone Guards to cover an item s sharp edges to prevent pouch punctures Allow foods and liquids to cool to room temperature before vacuum packaging Avoid overfilling the pou...

Page 6: ...ontrol Panel 5 Seal Bars Not Pictured Four 4 16 Double Wire Seal Bars 2 in each chamber VP400 Features 1 2 3 4 6 ARY Inc 11880 College Blvd Suite 550 Overland Park KS 66210 www VacMasterFresh com 800...

Page 7: ...ng time using the UP DOWN Buttons Cooling Illuminates to adjust vacuum time as well as during the cooling process During set up adjust the cooling using the UP DOWN buttons 3 Working Indicator Light I...

Page 8: ...ved Place catch cup underneath before removing drain bolt 7 Capture oil from pump When oil is completely drained replace and tighten bolt Dispose of old oil properly according to your local and state...

Page 9: ...t Up Adjusting the VP400 Timing Controls NOTE All timing adjustments must be made with the lid lock off and the lid open To adjust set the timing controls press the SET button on the control panel unt...

Page 10: ...accordingly NOTE The VP400 settings will always default to the most recently used settings on the machine To prolong the life of your seal bar set the cooling time to twice the sealing time TIP NOTE...

Page 11: ...ok for air pockets or air leaks If you notice that the product is not vacuum packaged tightly then increase the vacuum time by 5 seconds vacuum and seal again Seal confirmation Inspect the pouch seal...

Page 12: ...e air filter housing on the pump see Figure 1 below 2 Remove the 4 corner screws from end cap 3 Catch the gasket and spring from behind the end cap 4 Remove the old filter from housing 5 Insert new fi...

Page 13: ...first CO Code This stands for change oil Once complete press Set Up Down all 3 at the same time for 3 seconds This will reset and clear this code Mpa 1 2 3 4 5 Instructions 1 Press the program button...

Page 14: ...Suggested vacuum time should be set to 18 20 for liquids powders 35 40 is a good starting point for other products All settings are for 3 mil bags The seal time and cool down time should only be chang...

Page 15: ...n Vacuum pouch loses vacuum after being sealed Sharp items can poke small holes in pouches To prevent this cover sharp edges with VacMaster Bone Guard and vacuum in a new pouch Some fruits and vegetab...

Page 16: ...the lid 2 15 Amp Fuses 2x Can be used for replacing fuses located on the control transformer and the cord receptacle NSF models will have a fuse on the seal transformer 3 Seal Wire Used to replace sea...

Page 17: ...hing or freezing before vacuum packaging helps prevent this from occurring NOTE It is critical that food handling and storage are maintained at low temperatures You can reduce the growth of microorgan...

Page 18: ...Wire joint 2 13 Rubber tube 05 meter Part Part Name Qty 14 979033 Airbag seat 2 15 Airbag assembly 2 16 Seal bar seat 2 17 Guide sleeve 4 18 Sping 4 19 Wash 4 20 Nut 4 21 Pin 2 22 979123 Seal bar asse...

Page 19: ...O ring 1 23 M10x1 Joint 1 24 O ring 1 Part Part Name Qty 25 M14x1 Joint 1 26 979935 Rubber tube 0 6 meter 27 979156 Hose solenoid valve 1 28 Clip 2 29 T type connector 1 30 Valve seat 1 31 Rubber tube...

Page 20: ...7 Power cable 1 18 Door Latch 4 19 Door buckle double couplet 4 20 Cross headed screw 4 Part Part Name Qty 21 Straight handle 2 22 Electrical box cover 1 23 979135 Relay timer 1 24 Hull rear cover ass...

Page 21: ...Box 4x 30723 8 X 12 Vacuum Chamber Pouches 3 Mil 1 000 Box 4x 40751 8 X 12 Re Therm Vacuum Chamber Pouches 3 Mil 1000 Box 4x 30754 8 X 12 Vacuum Chamber Pouches 4 Mil 1000 Box 4x 50720 8 X 12 Zipper V...

Page 22: ...ber Pouches 4 Mil 500 Box 2x 40796 12 X 16 Re Therm Vacuum Chamber Pouches 4 Mil 500 Box 2x 30732 12 X 18 Vacuum Chamber Pouches 3 Mil 500 Box 2x 30757 12 X 18 Vacuum Chamber Pouches 4 Mil 500 Box 2x...

Page 23: ...applicable It excludes all other express oral or written warranties and all warranties implied by law with respect to the Goods including any warranties or merchantability or fitness for a particular...

Page 24: ...ll Rights Reserved VacMaster is a trademark or registered trademark of ARY Inc in the United States and other countries P O Box 412888 Kansas City MO 64141 VacMasterFresh com 800 821 7849 A Product of...

Reviews: