26
TROUBLESHOOTING
PROBLEM
SOLUTION
The device does not
start
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
•
Observe the operating temperature.
•
Check the filling level of the condensation tank and empty, it if
necessary. The FL indication (condensation tank full) must not
light up.
•
Wait for 10 minutes before restarting the device. If the device is
not starting, have the electrics checked by specialist company.
The device works with
reduced or no cooling
capacity
•
Check whether cooling mode is selected.
•
Check the proper fit of the air exhaust hose. In case of kinks,
bends or blockage in the hose, exhaust air cannot be
discharged. Clear the way for the exhaust air.
•
Check the position of the deflector. It should be opened to the
maximum.
•
Check the air filter(s) for dirt. If necessary, clean or replace the air
filter(s).
•
Check the minimum distance to walls or other objects. Position
the device a little more in the room's centre, if required.
•
Check whether any windows and/or doors of the room are
open. If so, close them. The window for the air exhaust hose has
to remain open nonetheless.
•
Check the temperature setting at the device. Reduce the set
temperature, if it is higher than the room temperature.
The device is loud or
vibrates
•
Check whether the device is set up in a stable and upright
position.
The compressor does
not start
•
Check whether the overheating protection of the compressor
has tripped. Disconnect the device from the mains and let it
cool down for approx. 10 minutes before reconnecting it.
•
Check whether the ambient temperature equals the target
temperature (in cooling mode). The compressor will not switch
on unless the respective temperature is reached.
•
The compressor may start up with a delay of 3 min, as it is