212
• VACON®
apfiff09 marine
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
P2.8.9.28 ID Run Current Kp
ID695
“ID Run Curr.Kp
Current controller gain during identification fun.
P2.8.9.29 Flux Saturation Ratio ID682
Relative nominal magnetizing current compared to non-saturated value
P2.8.9.30 DeadTimeComp.
ID1751
Dead Time Compensation in ns. Identified during 7 / DTC Identification run.
P2.8.9.31 DeadTieContCurL
ID1752
Continuous/discontinuous current limit for Dead Time Compensation. Identified during 7
/ DTC Identification run.
7.8.7 Fine Tuning parameters
P2.8.10.1 DeadTHWCompDisab
ID1750
Hardware dead time compensation 0 = enabled, 1 = disabled
P2.8.10.2 CurrMeasFCompTC
ID1554
P2.8.10.3 CurrLimOptions
ID1702
P2.8.10.4 AdConvStartShift
ID1701
P2.8.10.5
T: Identification
ID3520
P2.8.10.6
T: IdentOptions
ID3521