250
• VACON®
apfiff09 marine
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
P2.12.13 Disable Stop Lock
ID1086
Some parameters are locked during the Run state, with this parameter it’s possible to
bypass this Run State parameter lock. Be careful what you change and how big change
you make to those parameters.
P2.12.14 Reset Datalogger
ID1857
0 =
Auto
Datalogger signals will changed based on motor control mode automatically. Setting
datalogger from NCDrive will disable signal change automatically, to reactivate
automatic change set this parameter to 1.
1 =
Reset to Auto
When datalogger signals has been changed in NCDrive use this to set datalogger
back to Auto mode.
2 =
SW Default
System software default are activated and mode changes automatically to 4.
3 =
Auto Fast
Same as selection 0 but signals are recorded at fast time level. This selection will
increase system load.
4 =
No Change
Application will not make changes to signal.