6.8 Motor Control
6.8.1 Motor Control Basic Settings
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.8.1
0
5
0
600
0
=Frequency control
1
=OL Speed control
2
=Open Loop
3
=CL Speed Control
4
=Closed Loop
5
=Sensorless
P2.8.2
0
5
2
521
See P2.8.1
P2.8.3
Torque Select
0
5
2
1278
0
=Speed Control
1
=Maximum freq limit
2
=Ramp Output
3
=Min
4
=Max
5
=Window
Table 6-40. Motor Control basic parameters, G2.8
6.8.2 Open Loop
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.8.4.1
0
1
0
109
0
=Not used
1
=Automatic torque boost
P2.8.4.2
0
3
0
108
0
=Linear
1
=Squared
2
=Programmable
3
=Linear with flux optim.
P2.8.4.3
320.00
Hz
50.00
602
P2.8.4.4
10.00
200.00
%
100.00
603
n% x U
nmot
P2.8.4.5
0.00
P2.8.3.3
Hz
50.00
604
P2.8.4.6
0.00
100.00
%
100.00
605
n% x U
nmot
Parameter max. value =
P2.6.5
P2.8.4.7
0.00
40.00
%
0.00
606
n% x U
nmot
P2.8.4.8
I/f Start
0
1
0
534
0
=Disabled
1
=Enabled
P2.8.4.9
I/f Current
0.0
150.0
%
50.0
1693
P2.8.4.10
I/f Control Limit
0.0
300.0
%
10.0
1790
P2.8.4.11
MakeFluxTime
0
32000
ms
200
660
Table 6-41. Motor Control open loop parameters, G2.8.4