6.8.4 PMSM Control settings
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.8.6.1
PMSM Shaft
Position
0
65535
0
649
P2.8.6.2
Start Angle
Identification mode
0
10
0
1691
0
=Automatic
1
=Forced
2
=After Power Up
3
=Disabled
P2.8.6.3
Start Angle
Identification DC
Current
0.0
150.0
%
0.0
1756
P2.8.6.4
Polarity Pulse
Current
-10.0
200.0
%
0.0
1566
P2.8.6.5
Start Angle ID
Time
0
32000
ms
0
1755
P2.8.6.6
I/f Current
0.0
150.0
%
50.0
1693
P2.8.6.7
I/f Control Limit
0.0
300.0
%
10.0
1790
P2.8.6.8
Flux Current Kp
0
32000
5000
651
P2.8.6.9
Flux Current Ti
0
1000
25
652
P2.8.6.10
External Id
Reference
-150.0
150.0
%
0.0
1730
P2.8.6.11
Enable Rs
Identification
0
1
1
654
0
=No
1
=Yes
P2.8.6.12
Lsd Voltage Drop
-32000
32000
0
1757
P2.8.6.13
Lsq Voltage Drop
-32000
32000
0
1758
P2.8.6.14
EncIDCurrent
0.0
150.0
%
90.0
1734
P2.8.6.15
Polarity ID Mode
0
1
1737
P2.8.6.16
Polarity Pulse
Length
0
1000
ms
200
1742
P2.8.6.17
Polarity
Detection Angle
0.0
360.0
Deg
1.5
1748
P2.8.6.18
Angle
Identification
Mode
0
2
1749
P2.8.6.19
Current Control
Kp d
0
32000
%
1761
P2.8.6.20
Voltage Margin
0.0
120.0
%
1759
P2.8.6.21
Encoder ID Run
Mode
0
2
0
680
P2.8.6.22
PMSM Shaft
Position High
0
65535
0
681
P2.8.6.23
Start Angel Offset
-360,0
360,0
0
696
P2.8.6.24
VoltageCorr. Kp
0,000
32,000
0,100
1783
P2.8.6.25
VoltageCorr. Ki
0
32000
5000
1784
P2.8.6.26
FlxSaturRatio d
0,0
500,0
%
0,0
683
P2.8.6.27
FlxSaturRatio q
0,0
500,0
%
0,0
684
P2.8.6.28
LdqSatIDRun
0
1
0
677
P2.8.6.29
LdqIDWithAngle
0
1
0
678
Table 6-43. Motor Control PMSM parameters, G2.8.6