6.11 Master Follower
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.11.1
Master Follower
Mode
0
4
0
1324
0
=Not Used
1
=Master
2
=Follower
3
=Drive Synch Master
4
=Drive Synch Follower
P2.11.2
Follower Speed
Reference Select
0
18
17
1081
0
=AI1
1
=AI2
2
=AI1+AI2
3
=AI1-AI2
4
=AI2-AI1
5
=AI1xAI2
6
=AI1 Joystick
7
=AI2 Joystick
8
=Keypad
9
=Fieldbus
10
=Motor potentiometer
11
=AI1, AI2 minimum
12
=AI1, AI2 maximum
13
=Max frequency
14
=AI1/AI2 selection
15
=Encoder 1
16
=Encoder 2
17
=Master Reference
18
=Master Ramp Out
P2.11.3
Follower Torque
Reference Select
0
10
10
1083
0
=Not used
1
=AI1
2
=AI2
3
=AI3
4
=AI4
5
=AI1 joystick
6
=AI2 joystick
7
=Torque reference from
keypad, R3.5
8
=FB Torque Reference
9
=Master Torque OL
10
=Master Torque CL
P2.11.4
Follower Stop
Function
0
2
2
1089
0
=Coasting
1
=Ramping
2
=As Master
P2.11.5
MF Brake Logic
0
2
0
1326
Not used when Ramp
follower or in drive sync
mode
0
=Master or Own
1
=Own
2
=Master & Own, Master
monitors also follower
brake status.
P2.11.6
MF Mode 2
0
4
0
1093
See P2.11.1
P2.11.7
System Bus Fault
0
3
1
1082
0
=No response
1
=Warning
2
=Fault, stop acc. to
2.3.2
3
=Fault, stop by coasting
P2.11.8
System Bus Fault
Delay
0.00
320.00
s
3.00
1352
P2.11.9
Follower Fault
0
3
0
1536
0
=No response
1
=Warning
2
=Fault, stop acc. to
2.3.2
3
=Fault, stop by coasting
Table
6-52