vacon • 26
CANopen protocol description
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
To restore parameters, write 0x64616F6C (ASCII "load") into the sub-index by using the SDO
protocol. Default object values are selected after reset. Restore all default parameter restores CiA-
402 default parameters (refer to Chapter 8.2.2.2). Bypass parameter set is described in Chapter 8.3.
* The bypassed set disables the CIA- 402 drive profile and resets the PDO mapping to the vendor specific
configuration. See Chapter 8.2 and Chapter 8.3 for more information.
Table 49: 0x1011 Restore default parameters
Index
Sub-index
Name
Data type
Access
0x1011
0
Highest sub-index supported
UNSIGNED8
ro
1
Restore all default
parameters
UNSIGNED32
r/w
4
Restore bypass parameter
set*
UNSIGNED32
r/w
5
Restore Puller parameter
set
UNSIGNED32
r/w
6
Restore Co-Extruder param-
eter set
UNSIGNED32
r/w