background image

All equipment sold under the VACPAK-IT trademark and used for commercial purpose is warranted against 

defects in materials and workmanship. The warranty runs for 1 year from time of purchase and is for the 

benefit of the original purchaser only. All other warranties, Expressed or Implied, Statutory or otherwise, 

including Without Limitation and any implied warranty of Merchantability or Fitness for Purposes are 

excluded. The seller shall in no event be liable for direct, indirect, or consequential damages in connection 

with VACPAK-IT commercial products. 

This warranty is not effective if damage occurs due to accident, carelessness, improper installation, lack 

of proper set-up, supervision when required, or if the equipment is installed or operated in any manner 

contrary to the installation and operating instructions. Work performed by unauthorized personnel or 

unauthorized service agencies voids this warranty. This warranty explicitly does not apply to, and VACPAK-

IT is not responsible for, any warranty claims made on products sold or used outside of the United States.

Cleaning

Storage

This model is intended for indoor use only at commercial food service establishments.
It is designed to provide precise temperature control of water for closed loop circulation.
To extend the life of this model, please clean every 20 uses, or 100 hours of use.

1.  Fill a container with a solution of water and vinegar.
2.  Turn the circulator head on and let it circulate water for 20 minutes.
3.  Repeat this process with a container full of clean water to rinse.
4.  To clean the filter, unplug the machine and allow it to cool down. 
  Open the machine housing and use a soft brush to remove particles from filter.

1.  Store the model in an upright position after use to prevent water from 

  leaking into the top portion.
2.  If liquid gets into the top part of the model, turn the power off and dry 

  with a clean towel before use.

MAINTENANCE

4.

ISSUE

REMEDY

No power

to the unit

•  Ensure the machine is properly plugged into a grounded outlet.
•  Check the power cord for tears, frays, or other damage. 

Do not use machine if the power cord is damaged.

The unit is no

longer heating

•  Ensure that the water level is between the MIN and MAX fill lines 

marked on the head. If not, allow the unit to cool and add water 

until the level reaches between these 2 marks.

Summary of Contents for SV08

Page 1: ...y 120V 1200W 10 Amps 5 15P SV08KIT Sous Vide Immersion Circulator Head 8 Gallon Water Tank 120V 1200W 10 Amps 5 15P Thank you for purchasing this VACPAK IT equipment Before operating the equipment please carefully read the following operating and safety instructions SOUS VIDE IMMERSION CIRCULATOR ...

Page 2: ...Features 1 Safety Instructions 2 Operating Instructions 3 Control Panel 3 Maintenance Guide 4 Troubleshooting 4 Warranty 4 More from VACPAK IT 5 ...

Page 3: ...1 FEATURES CONTROL PANEL WATER LEVEL INDICATORS PUMP INSIDE COOLING FAN INSIDE HEATING ELEMENT INSIDE ADJUSTABLE CLAMP ...

Page 4: ...equipment with steel wool 9 Keep equipment and power cord away from open flames electric burners or excessive heat 10 DO NOT operate equipment in public areas and or around children 11 DO NOT operate if equipment has been damaged or is malfunctioning in any way 12 Only use this model for intended purpose 13 DO NOT use this model to heat oil grease or any other liquid besides water 14 DO NOT put yo...

Page 5: ...ting the water 11 Stop Button Press to stop operation 1 7 9 10 3 2 11 6 5 4 8 OPERATING INSTRUCTIONS CONTROL PANEL 1 Select a container for water bath A water container with a 6 depth is required to use with this equipment This unit is designed to heat and circulate up to 8 gallons of water 2 Attach the circulator head to the container via the adjustable clamp Make sure the circulator head is fixe...

Page 6: ...e United States Cleaning Storage This model is intended for indoor use only at commercial food service establishments It is designed to provide precise temperature control of water for closed loop circulation To extend the life of this model please clean every 20 uses or 100 hours of use 1 Fill a container with a solution of water and vinegar 2 Turn the circulator head on and let it circulate wate...

Page 7: ...CHAMBER VACUUM PACKAGING MACHINES VACUUM PACKAGING BAGS Intertek MORE FROM V ACPAK IT 5 ...

Reviews: