background image

VDH-DXG Series Hardware Manual

 

 

12 

 

 
Q 22.

 

Download files cannot be played back. 

A : The possible causes: 

1. No player 
2. No graphic accelerator with DX8.1 or above 
3. Save as AVI files and play with MEDIA PLAYER 

   
Q 23.

 

Forget the administrative password or internet password 

A : The possible solution: 

 
1. 

Please contact local customer service staff or call the customer service 

phone headquarters, we will guide you how to solve by the machine 
type and version of the program. 

 
 

2.

 

Maintenance 

 

Damped dust on the PCB board will cause a short circuit and will do 
something wrong to the DVR or damage it. For long-term stability of the 
DVR, regularly brush the circuit boards, connectors, fans and chassis to 
remove dust. 

 

Please ensure the project is well-grounded, so images, audio signal will 
not be disturbed. At the same time, we can protect the DVR from static 
or inductive voltage damage. 

 

Do not remove audio/video cables and RS-484 when the DVR is 
powered on, or they will be damaged. 

 

Do not use the TV interface in the DVR video output (VOUT), or the DVR 
output circuit will be damaged easily. 

 

Do not turn off the power switch directly to shut down the DVR. Use the 
menu shutdown or OFF button on the front panel (press more than three 
seconds) to turn off the power automatically to avoid hard Drive crash. 

 

Keep the DVR away from heats and hot places. 
Keep the DVR chassis well-ventilated for better heat dissipation. 

 

Have regular checks and system maintenance 
 
 

 

 

Summary of Contents for VDH-DXG Series

Page 1: ...Hardware Manual G series 2013 SEP V1 0 ...

Page 2: ...E Product appearance 4 1 Front Panel 4 2 Rear Panel 5 3 Installation Illustration 6 Video input 6 Connections for video outputs 6 Audio Inputs 7 Audio Output 7 AlarmIn AlarmOut connections 7 RS 485 connection 8 F Q A and Maintenance 8 1 Q A 8 2 Maintenance 12 G Appendix Specifications 13 1 8 CH 960H H 264 DVR 13 2 4 CH 960H H 264 Real Time DVR 15 3 4 CH 960H H 264 DVR 17 ...

Page 3: ...s In the shortest time we will solve the problems you have during using When not using the remote control for a long time take out the inside battery To prevent the control from the damage coming from battery leakage If this equipment connects to outdoor cameras or other external alarm devices ground this equipment to prevent it from electrical surges This DVR supports remote video monitoring via ...

Page 4: ...ty in banks telecommunications power stations justice transport intelligence communities factories warehouses resources water conservancy facilities and other categories 2 Main functions Pentaplex Operation which can Record Playback Remote Connection mobile phone watch video backup Support 2 fixed internal Hard Drives single hard drive can be up to 4TB Support RAID recording to protect important v...

Page 5: ...are connected firmly Front Rare panels The key functions of the front panel and the interfaces of the rear panel are described in detail in the manual Please carefully check the plate or foil on the rear panel of the product to see if it is the model you ordered Information on the rear panel is important for our service so keep it properly Before contacting us you will need to provide your model t...

Page 6: ...the speed Choose your choice to forward UP DOWN To move up or down of the selection setting in the UI menu Under the live mode of Single Quad 8 9 display use the button to control video display LEFT RIGHT To move left or right of the selection setting in the UI menu Under the living mode change to Single Quad 8 9 division display Menu Under the live viewing mode press MENU to enter the main menu P...

Page 7: ...l 8ch DVR illustration 1 1 8 CH Video Input BNC 2 Video Output BNC 3 Audio Output BNC 4 HD digital output 5 VGA output 6 Audio Input 7 LAN Port 8 USB 9 RS 485 PORT 10 Alarm optional 12 DC12 Power Input 12 Power Switch RS 485 port DC12 Power Input ...

Page 8: ... the normal operation of the cameras Make sure the transmission cables are stable and reliable Adopt high quality well shielded coaxial cables and choose the right model based on the transmission distance If the distance is too far use shielded twisted pair video compensation equipment optical transmission and other ways to ensure signal quality based on the specific circumstances Video cable shou...

Page 9: ...mpedance headphones powered speakers or other sound devices through a power amplifier When the external speakers and microphones cannot achieve spatial segregation it is prone to the phenomenon of whistling You may adopt following actions 1 Using better directional microphones 2 Adjust the speaker volume to make it lower than the value of the generated howling 3 Using sound absorbing materials for...

Page 10: ...power on DVR will restart after several minutes or the screen freezes A The possible causes 1 Unstable or low input voltage 2 The hard drive has bad sectors or cable error 3 Low adaptor power 4 Front video signal not stable 5 High temperature too much dust and the machine runs in a bad condition 6 DVR hardware error Q 3 HDD not found after power on A The possible causes 1 No power for the Hard Dri...

Page 11: ...existing file system 4 Desired files are overwritten 5 Recording not enabled Q 7 Bad image when playback A The possible causes 1 Low recording quality 2 Once data error when reading or small bit rate or fuzzy when playback please reboot machine 3 Wrong data cable or jumper error in the hard disk 4 Hard Disk error 5 DVR hardware error Q 8 No audio sound A The possible causes 1 Not powered microphon...

Page 12: ...n by using client software or Web browsers A The possible causes 1 Operating system is Win98 or Win Me and the client software cannot be installed or displayed normally Upgrade the operating system to Win2000sp4 or above or use lower versions of the client software 2 ActiveX control blocked install the ActiveX control in the attached CD 3 DX8 1 or above not installed upgrade the display driver 4 N...

Page 13: ... A The possible causes 1 Wrong alarm settings 2 AlarmOut turned on manually 3 Input equipment error or wrong connections 4 Wrong firmware problem Upgrade firmware to fix it Q 19 Alarms do not work A The possible causes 1 Wrong alarm setting 2 Wrong alarm wiring 3 Wrong AlarmIn signal 4 One alarm equipment involves into two loops Q 20 The remote controller cannot work A The possible causes 1 Wrong ...

Page 14: ... DVR regularly brush the circuit boards connectors fans and chassis to remove dust Please ensure the project is well grounded so images audio signal will not be disturbed At the same time we can protect the DVR from static or inductive voltage damage Do not remove audio video cables and RS 484 when the DVR is powered on or they will be damaged Do not use the TV interface in the DVR video output VO...

Page 15: ...S CH PAL Recording quality Lowest Low Normal Good High Highest Recording mode Continuous Schedule Motion Alarm Manual detection Zones 396 22 18 grid Pre recording 1 30 seconds Post recording 10 300 seconds Display mode Single Quad 8 Split 9 Split Sequence Backup Formats AVI use defined format Media interface USB Network Player Yes Networking Stream 960H D1 HD1 CIF QCIF Playback YES Network protoco...

Page 16: ...iPhone Android Windows Mobile Symbian BlackBerry Support monitoring including audio playback and two way audio Intelligent functions YES Motion detection removals entry eriting detection Central Management System YES Hybrid Digital Analogue YES General Specifications Operating conditions 0 to 46 humidity 20 to 80 Power DC 12V 2A AC100V 240V 50 60HZ Net weight total weight 1 6kgs not including HDD ...

Page 17: ...or 960H D1 HD1 CIF Frame per second 4 CH 960H 30FPS CH NTSC 4 CH 960H 25FPS CH PAL Recording quality Worse poor fair good very good Nice Recording mode Always Schedule Motion Alarm Manual Motion detection By grid setting motion area can be 396 22 18 blocks Pre recording 1 30 seconds Post recording 10 300 seconds Display Mode Single Quad Sequence Backup Formats AVI User defined Media interface USB ...

Page 18: ...rmware update USB update remote network update Network time protocol YES Smart phone support iPhone Android Windows Mobile Symbian BlackBerry Support 4 ch monitoring including audio playback and two way audio Intelligent functions YES Motion detection removals eniting exiting detection Central Management System YES Hybrid Digital Analogue YES General Specifications Operating conditions 0 to 46 hum...

Page 19: ...or 960H D1 HD1 CIF Frame per second 4CH 960H 24FPS CH NTSC 4CH 960H 22FPS CH PAL 4CH D1 30FPS CH NTSC 4CH D1 25FPS CH PAL Recording quality Worse poor fair good very good Nice Recording mode Always Schedule Motion Alarm Manual Motion detection By grid setting motion area can be 396 22 18 blocks Pre recording 1 30 seconds Post recording 10 300 seconds Display Mode Single Quad Sequence Backup Format...

Page 20: ...more than 20 languages Firmware update USB update remote network update Network time protocol YES Smart phone support iPhone Android Windows Mobile Symbian BlackBerry Support 4 ch monitoring including audio playback and two way audio Intelligent functions YES Motion detection removals eniting exiting detection Central Management System YES Hybrid Digital Analogue _ General Specifications Operating...

Page 21: ...Manufacturer FUHO TECHOLOGY CO LTD No 30 Lane 726 Sec 3 Jinma Rd Changhua City Phone 886 4 751 2881 Fax 886 4 751 6631 ...

Reviews: