page 36 of 152
Use and operation
When switching on the controller CVC 3000 for the very first time, a menu
to select the language of the controller menu is displayed. Select the de-
sired language (e.g., ”English”) by turning the selection knob and press
to confirm. Then select the pressure unit (”mbar”, ”Torr” or ”hPa”) in the
same way.
It is possible to access the language selection menu at any time
by switching on the controller while keeping the selection knob
pressed.
Installation
Read the document ”Safety information for
vacuum equipment” and observe the in-
structions contained therein!
1
Safety information
for vacuum equipment
Sicherheitshinweise für Vakuumgeräte
Safety information for vacuum equipment
Avis de sécurité pour des dispositifs à vide
Указания за безопасност за вакуумни уреди
真空设备的安全信息
Bezpečnostní upozornění pro vakuové přístroje
Sikkerhedsregler for vakuumudstyr
Ohutusnõuded vaakumseadmetele
N
otas sobre la seguridad para equipos de vacío
Vakuumilaitteen turvallisuustiedot
Υποδείξεις ασφάλειας για αντλίες κενού
Sigurnosne napomene za vakuumske uređaje
A vákuum-készülékekkel kapcsolatos biztonsági tudnivalók
Istruzioni di sicurezza per apparecchi a vuoto
真空装置を安全に取り扱うために
진공
장비에
대한
안전
정보
Vakuuminės įrangos saugos informacija
Vakuuma iekārtu drošības noteikumi
Veiligheidsvoorschriften voor vacuümapparaten
Wskazówki bezpieczeństwa do urządzeń próżniowych
Informação de Segurança para Equipamento que funciona a Vácuo
Instrucţiuni de siguranţă pentru aparatele de vidare
Указания по технике безопасности при работе с вакуумными устройствами
Säkerhetsinformation för vakuumutrustning
Varnostni nasveti za vakuumske naprave
Bezpečnostné pokyny pre vákuové zariadenia
Vakumlu cihazlar için güvenlik uyarıları
DE
EN
FR
BG
CN
CZ
DA
EE
ES
FI
GR
HR
HU
IT
JP
KR
LT
LV
NL
PL
PT
RO
RU
SE
SI
SK
TR
Remove the product from its packing-box.
+
Make sure ventilation is adequate, especially if the pump
is installed in an enclosure, or if the ambient temperature
is elevated. Provide external ventilation, if necessary.
2 in
(5 cm)
2 in
(5 cm)
NOTICE
Put the pump in place.
Keep a minimum distance of 2 in (5 cm) be-
tween the cooling fan and surrounding items
(e.g., housing, walls, etc.), or else install an ex-
ternal automatic ventilation system.
Summary of Contents for MV 10C NT VARIO o.C.
Page 34: ...page 34 of 152 1 8 2 9 18 PC 3012 NT VARIO EK Peltronic 12 11 16 8 17 3 4...
Page 104: ...page 104 of 152 2 3 size 1 2x 4...
Page 105: ...page 105 of 152 6 5 7 4 4x...
Page 106: ...page 106 of 152 9 8 1 2 2 5 mm 2 5 mm 10 ME 16C NT VARIO MD 12C NT VARIO MV 10C NT VARIO...
Page 108: ...page 108 of 152 12 Emission condenser Peltronic 4 4x 11A 13 4 2x...
Page 109: ...page 109 of 152 15 14 4 4x Don t loosen this screw 15A 16...
Page 110: ...page 110 of 152 16 17 5 2x 15A 1 2 3 1 4 1 4 3 2x 5...
Page 111: ...page 111 of 152 19 20 18 5 2x...
Page 113: ...page 113 of 152 21 2 5 mm Replacing the diaphragms 22 23 696867 696839 Clean 5 8x...
Page 114: ...page 114 of 152 24 25 26 1 2...
Page 115: ...page 115 of 152 27 3 28 29 Pay attention to number of washers...
Page 118: ...page 118 of 152 36 37 38 Clean...
Page 119: ...page 119 of 152 39 40 41 IN IN EX EX 696867 696839 4x...
Page 120: ...page 120 of 152 42 43 44 IN EX T20 4x 2 2 ft lbf 3 Nm...
Page 121: ...page 121 of 152 45 46 47 Maintain all pump heads in the same way...
Page 125: ...page 125 of 152 2 size 2 2x 3 4A Version A valve 24 4 mm...
Page 126: ...page 126 of 152 5A 696839 24 4 mm 26 mm 4B 5B 696839 37 mm 40 mm Version B valve 37 mm...
Page 127: ...page 127 of 152 6 7 size 2 2x 7A ME 16C NT VARIO MD 12C NT VARIO MV 10C NT VARIO size 2 2x...
Page 129: ...page 129 of 152 49 Assembling the pump housing 50 51 5 2x 8 9 ft lbf 12 Nm...
Page 130: ...page 130 of 152 52 53 54 5 2x 8 9 ft lbf 12 Nm...
Page 131: ...page 131 of 152 55 55A 1 2 3 3 2x 55A 56...
Page 132: ...page 132 of 152 56 4 4x 3 7 ft lbf 5 Nm 58 4 4x 3 7 ft lbf 5 Nm 57 4 2x 3 7 ft lbf 5 Nm...
Page 133: ...page 133 of 152 59 60 61...
Page 135: ...page 135 of 152 62 63 4 4x 3 7 ft lbf 5 Nm 64...
Page 136: ...page 136 of 152 65 66 67 size 1 2x...
Page 137: ...page 137 of 152 68 69...
Page 140: ...page 140 of 152 4 638821 638821 5 6...
Page 141: ...page 141 of 152 7 T20 4x size 1 4x 8...
Page 149: ...page 149 of 152...
Page 150: ...page 150 of 152...
Page 151: ...page 151 of 152...