background image

page 15 of 17

Documents are only to be used and distributed completely and unchanged. It is strictly the users´ responsibility to check
carefully the validity of this document with respect to his product. manual-no.: 999039 / 16/12/2009

Health and safety clearance form

Declaration concerning safety, potential hazards and safe disposal of waste, e. g. used oil.

Safety and health of our staff, laws and regulations regarding the handling of dangerous goods, occupational health and safety
regulations, safety at work laws and regulations regarding safe disposal of waste, e. g. waste oil, require that for all pumps and
other products this form must be sent to our office duly completed and signed before any equipment is dispatched to our
premises.

 Products will not be accepted for any procedure and handling and repair / DKD calibration will not start

before we have received this declaration.

a) Fax or post a

 completed copy of this form

 to us in advance. The declaration must arrive before the equipment.

 Enclose

a second, completed copy with the product. 

If the product is contaminated you must notify the carrier (

GGVE, GGVS,

RID, ADR

).

b) Inevitably, the repair process will be delayed considerably, if this information is missing or this procedure is not obeyed. We

hope for your understanding for these measures which are beyond our control and that you will assist us in expediting the
repair procedure.

c )

Make sure that you know all about the substances which have been in contact with the equipment and that all
questions have been answered correctly and in detail.

1. Product (Model):

........................................

2. Serial No.:

..................................................

3. List of substances in contact with the

equipment or reaction products:

3.1 Chemical/substance name,

chemical symbol:

a) ...................................................................

b) ...................................................................

c) ...................................................................

d) ...................................................................

3.2 Important information and precautions,

e. g. danger classification:

a) ...................................................................

b) ...................................................................

c) ...................................................................

d) ...................................................................

4. Declaration (please mark as applicable):

4.1 for non dangerous goods:

We assure for the returned product that
- neither toxic, corrosive, biologically active, explosive, radio-

active  nor contamination dangerous in any way has
occurred.

- the product is free of dangerous substances.
- the oil or residues of pumped media have been drained.

4.2 for dangerous goods:

We assure for the returned product that
- all substances, toxic, corrosive, biologically active, explo-

sive, radioactive or dangerous in any way which have
pumped or been in contact with the product are listed in 3.1,
that the information is complete and that we have not
withheld any information.

- the product, in accordance with regulations, has been

❑ 

cleaned    

 ❑

 decontaminated     

 sterilized.

5. Way of transport / carrier:

...........................................................................................

Day of dispatch to VACUUBRAND:

...........................................................................................

If the paint is damaged, we wish a repaint or
a replacement of parts due to optical
aspects at our expense

 (see ”Notes on return

to the factory”):

 yes

 no

We declare that the following measures -
where applicable - have been taken:

- The oil has been drained from the product.

Important: Dispose of according to national
regulations.

- The interior of the product has been cleaned.
- All inlet and outlet ports of the product have been

sealed.

- The product has been properly packed, if necessary,

please order an original packaging (costs will be
charged) and marked as appropriate.

- The carrier has been informed about the hazardous

nature of the goods (if applicable).

We assure

 VACUUBRAND that we accept liability for any

damage caused by providing incomplete or incorrect
information and that we shall indemnify VACUUBRAND from
any claims as regards damages from third parties.

We are aware 

that as expressed in § 823 BGB  (Public

Law Code of Germany) we are directly liable for injuries or
damages suffered by third parties, particularly
VACUUBRAND employees occupied with handling/
repairing the product.

Signature: ...........................................................................

Name (print): ......................................................................

Job title (print): ...................................................................

Company´s seal: ...............................................................

Date: ...................................................................................

VACUUBRAND GMBH + CO KG

-Technology for Vacuum Systems-

©

 

2003 VACUUBRAND GMBH + CO KG Printed in Germany

Alfred-Zippe-Str. 4 - 97877 Wertheim
Tel.: +49  9342 808-0 - Fax: +49 9342 808-450
E-Mail: info@vacuubrand.de
Web: www.vacuubrand.com

Summary of Contents for VAP 5

Page 1: ...buted completely and unchanged It is strictly the users responsibility to check carefully the validity of this document with respect to his product manual no 999039 16 12 2009 Vacuum gauges VAP 5 DVR...

Page 2: ...controller VACUUBRAND vacuum gauges are the result of many years of experience in construction and practical operation of these vacuum gauges combined with the latest results in material and manufact...

Page 3: ...his product manual no 999039 16 12 2009 Attention Important notes Not permitted Misuse may cause damage Caution Hot surface Isolate equipment from mains Note Contents Safety information 4 Technical d...

Page 4: ...ination withVACUUBRAND genuine accessories Obey all other relevant safety requirements e g accident prevention regulations for working in laboratories and explosion protection guidelines and provide p...

Page 5: ...sary is approximately decontaminated before starting maintenance Use only genuine spare parts and accessories Otherwise safety and performance of the equipment as well as the electromagnetic compatibi...

Page 6: ...0 1 n i h t i w e u l a v d e t a c i d n i f o 0 1 r a b m 0 0 1 2 r a b m e g n a r t i g i d 1 r a b m 1 t n e i c i f f e o c e r u t a r e p m e T d e i f i c e p s t o n K r a b m 7 0 0 n o i t...

Page 7: ...peration Display Rear side key button for digital adjustment and electronic scale conversion pressure unit at the side of the housing male connector for mains cable thread M8 for stand rod female conn...

Page 8: ...yed with a resolution of 0 1 mbar in the range of 0 1 to 10 mbar and with a resolution of 1 mbar for pressures 10 mbar Preparing for operation Connect gauge head with connecting cable to the female co...

Page 9: ...ace the actual pressure value can be read out The single abbreviations of a command are separated by underscores ASCII 5FH The string is terminated with CR LF ASCII 0DH ASCII 0AH r e t e m a r a p e c...

Page 10: ...d a e h e g u a G d e t a n i m a t n o c r o r e t l i f e v i t c e t o r p n a e l C y r a s s e c e n f i e n o w e n e s u d n a d a e h e g u a g n a e l C t s u j d a e r g n o r w s i t n e m...

Page 11: ...h the pumped media see Technical data If the vacuum system is contaminated oil particles etc Replace the protective filter cat no 63 87 29 in the gauge head VSP 5 if necessary Using small screw driver...

Page 12: ...not be adjusted under vacuum replace gauge head Push key button at the side of the housing with a pencil tip or a small screwdriver Status indication readjustment Set is displayed Disconnect leads fro...

Page 13: ...ey button to adjust the display to the reference pressure at the vacuum line within the range of 0 10 mbar Note If the nominal ultimate vacuum of a diaphragm pump is used as reference vacuum the accur...

Page 14: ...ry product returned for repair We submit quotations only on request and always at the customer s expense If an order is given the costs incurred are offset from the costs for repair or from the pur ch...

Page 15: ...for the returned product that neither toxic corrosive biologically active explosive radio active nor contamination dangerous in any way has occurred the product is free of dangerous substances the oil...

Page 16: ...agreement of the manufacturer Par la pr sente nous d clarons que le dispositif d sign ci dessus est conforme aux prescriptions de base des directives EU applicables et indiqu s en ci que concerne con...

Page 17: ...obtained under test conditions for specific applications depend on a number of factors beyond our control It is therefore strictly the users responsibility to very carefully check the validity of app...

Reviews: