background image

page 2 of 17

Documents are only to be used and distributed completely and unchanged. It is strictly the users´ responsibility to check
carefully the validity of this document with respect to his product. manual-no.: 999039 / 16/12/2009

After sales service: Contact your local dealer or call +49 9342 808-193.

Dear customer,

Your VACUUBRAND vacuum gauge shall support you at your work for a long time without any trouble and
with full load output. Thanks to our large practical experience we attained much information how you could
add to an efficient application and to personal safety. Please read these instructions for use prior to the
initial start-up of your controller.
VACUUBRAND vacuum gauges are the result of many years of experience in construction and practical
operation of these vacuum gauges combined with the latest results in material and manufacturing technology.

Our quality maxim is the ”zero fault principle”:

Every delivered vacuum gauge is tested extensively including an endurance run. Due to this endurance
run, also faults, which occur rarely, are reported an can be corrected. Every single vacuum gauge is tested
on achievement of the specification after the endurance run.

Every  VACUUBRAND controller leaving our factory achieves the specification. We feel obliged to
this high quality standard.

We are aware that the controller should not draw a part of the real work and we hope to contribute with our
products to an effective and troublefree realisation of your work.

Yours
VACUUBRAND GMBH + CO KG

Summary of Contents for VAP 5

Page 1: ...buted completely and unchanged It is strictly the users responsibility to check carefully the validity of this document with respect to his product manual no 999039 16 12 2009 Vacuum gauges VAP 5 DVR...

Page 2: ...controller VACUUBRAND vacuum gauges are the result of many years of experience in construction and practical operation of these vacuum gauges combined with the latest results in material and manufact...

Page 3: ...his product manual no 999039 16 12 2009 Attention Important notes Not permitted Misuse may cause damage Caution Hot surface Isolate equipment from mains Note Contents Safety information 4 Technical d...

Page 4: ...ination withVACUUBRAND genuine accessories Obey all other relevant safety requirements e g accident prevention regulations for working in laboratories and explosion protection guidelines and provide p...

Page 5: ...sary is approximately decontaminated before starting maintenance Use only genuine spare parts and accessories Otherwise safety and performance of the equipment as well as the electromagnetic compatibi...

Page 6: ...0 1 n i h t i w e u l a v d e t a c i d n i f o 0 1 r a b m 0 0 1 2 r a b m e g n a r t i g i d 1 r a b m 1 t n e i c i f f e o c e r u t a r e p m e T d e i f i c e p s t o n K r a b m 7 0 0 n o i t...

Page 7: ...peration Display Rear side key button for digital adjustment and electronic scale conversion pressure unit at the side of the housing male connector for mains cable thread M8 for stand rod female conn...

Page 8: ...yed with a resolution of 0 1 mbar in the range of 0 1 to 10 mbar and with a resolution of 1 mbar for pressures 10 mbar Preparing for operation Connect gauge head with connecting cable to the female co...

Page 9: ...ace the actual pressure value can be read out The single abbreviations of a command are separated by underscores ASCII 5FH The string is terminated with CR LF ASCII 0DH ASCII 0AH r e t e m a r a p e c...

Page 10: ...d a e h e g u a G d e t a n i m a t n o c r o r e t l i f e v i t c e t o r p n a e l C y r a s s e c e n f i e n o w e n e s u d n a d a e h e g u a g n a e l C t s u j d a e r g n o r w s i t n e m...

Page 11: ...h the pumped media see Technical data If the vacuum system is contaminated oil particles etc Replace the protective filter cat no 63 87 29 in the gauge head VSP 5 if necessary Using small screw driver...

Page 12: ...not be adjusted under vacuum replace gauge head Push key button at the side of the housing with a pencil tip or a small screwdriver Status indication readjustment Set is displayed Disconnect leads fro...

Page 13: ...ey button to adjust the display to the reference pressure at the vacuum line within the range of 0 10 mbar Note If the nominal ultimate vacuum of a diaphragm pump is used as reference vacuum the accur...

Page 14: ...ry product returned for repair We submit quotations only on request and always at the customer s expense If an order is given the costs incurred are offset from the costs for repair or from the pur ch...

Page 15: ...for the returned product that neither toxic corrosive biologically active explosive radio active nor contamination dangerous in any way has occurred the product is free of dangerous substances the oil...

Page 16: ...agreement of the manufacturer Par la pr sente nous d clarons que le dispositif d sign ci dessus est conforme aux prescriptions de base des directives EU applicables et indiqu s en ci que concerne con...

Page 17: ...obtained under test conditions for specific applications depend on a number of factors beyond our control It is therefore strictly the users responsibility to very carefully check the validity of app...

Reviews: