background image

25

24

VADA FLOW BOSS 

DIGITAL WATER SWITCHING UNIT

 

VFB-DSU 

INSTALLATION MANUAL

Removing the unit for service

1.  Switch off power to the unit before 

proceeding.

8.  If at any time the tank fills with rainwater 

during these lockout periods, the system 
can be overridden by turning power off to 
the switching unit for 10 seconds which will 
reset the system.

EVENT

RESET TIME

1st lockout

24 hours

2nd lockout

7 days

The Vada Flow Boss Digital 
Switching Unit is a warm, dry 
environment for hibernating 
insects. Insects can cause 
electrical malfunction. Ensure  
that your property is vermin free.

The unit is electrically connected. 
Ensure that it is isolated from 
electrical supply during installation 
and any subsequent service work.

Unit should only be serviced by 
qualified personnel or licensed 
service agent.

OFF

6.  If rainwater is detected the system will 

revert to normal operation.

7.  If no rainwater is detected then the 

switching unit will go to a further 7 day lock 
out as per step 4. The unit will continue 
to automatically recheck every 7 days for 
rainwater in the tank.

7

DAYS

OFF

SERVICE & MAINTENANCE

FAULT MODE

2.  Close shut off isolation valve at inlet,  

outlet, and water tank gate valve. Carefully 
release all pressure from the pump and 
piping system.

Note: 

Never tighten or loosen fittings while the 

pump is operating.

To reset from ‘loss of prime’ mode

1.  Turn off power 10 seconds, turn power 

supply back on. 

10

SEC

OFF

Summary of Contents for FLOW BOSS VFB-DSU

Page 1: ...DIGITAL WATER SWITCHING UNIT INSTALLATION MANUAL VFB DSU ...

Page 2: ...ce number Product serial number Product model number A smooth day is a good day That s why Vada is dedicated to creating pump solutions that you can count on With a focus on easy selection simple installation and high quality you can hold your head high knowing your reputation is protected It s Vada Performance simplified THANK YOU Scan for set up support ...

Page 3: ...PA 1 bar Max operating pressure 1000kPA 10 bar Minimum flow rate 1 lpm Voltage 1 230 240V 50Hz Maximum electrical load 10A 2400W IP Rating IP44 Vada strongly recommends installing the float switch supplied in the tank on site Installing a float switch prevents air from re entering the suction line and damaging your Vada product Installing a float switch also reduces build up from tank debris enter...

Page 4: ...ion pipe internal diameter must be no smaller than 25mm x2 mesh inline filters Discharge pipe internal diameter must be no smaller than 25mm 16mm hole saw Thread tape Access to a 10A outdoor power point Inline filter AKA Y Strainer Isolation valve Swing check valve Float switch tank If the incoming mains pressure to your property is greater than the specified 1000 kPa 10 bar you MUST fit a pressur...

Page 5: ... type of device to the entire house will extend the life of other appliances such as washing machines hot water service and dishwashers This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person respons...

Page 6: ...pple from the union Rethread the nipple into the switching unit making sure the union nut remains on the nipple Re join the union to complete connection 6 Connect the VFB DSU to the discharge port on the pump 7 Connect the incoming mains water supply to the MAINS port on the VFB DSU This is marked MAINS with an arrow pointing out of the VFB DSU indicating water flow direction Note Brace this fitti...

Page 7: ...pply by either a Hard wiring Local authorities may require the pump to be hard wired Important If this applies to you the electrical connection must be done by a qualified electrician with pump knowledge according to the National wiring rule AS NZS 3000 and or any local council requirements WARNING Hazardous voltage can cause shock burn or cause death The supply voltage for the Digital Water Switc...

Page 8: ...e This indicates to the switching unit that there is no water in the tank and to switch to mains supply operation 4 Open an outlet on the household side of the VFB DSU The VFB DSU should now be allowing mains water to supply the demand 5 Close the tap and replace the float switch connection If there are any variations to these outcomes please refer to the Troubleshooting section on page 28 70mm ab...

Page 9: ...nstallation will be random 4 To set the date and time press the Time Set button 5 Press either up or down arrow to select the correct day of the month When the correct value is observed press the Time Set button again 9 In the event the user inputs incorrect information the Invalid Data screen will appear 10 The VFB DSU has been set to its basic settings For advanced settings and additional functi...

Page 10: ... which the pump will stop aka cut out 1 Press the RESET button again to select the Cut Out Flow 2 Press the up or down arrow to select the appropriate cut out level Note It is recommended the Cut Out flow rate be 1 lpm Minimum Pressure 1 Press the RESET button until you reach Min Pressure 2 Press the up or down arrow to select the appropriate pressure Note The Min Max pressure required for the swi...

Page 11: ...50Hz Max electrical load 10A 2400W Power standby 3 5W Control power on 30W IP rating IP44 Min flow rate 1lpm Min mains pressure 1 bar Max operating pressure 10 bar Min max water temperature 1 C 40 C Min max ambient temperature 1 C 40 C CONNECTION Mains water supply inlet 25mm FI BSP Pump connection 25mm FI BSP Water outlet connection 25mm FI BSP TECHNICAL INFORMATION C F H I A B J G D E A 52mm B 1...

Page 12: ...ystem will automatically default to mains water supply When power is restored the switching unit will revert to normal operation Loss of Mains Supply Water If town supply water is shut off in your area the switching unit may not be able to detect water demand in the household e g if the toilet cistern needs refilling You can override normal control and start the pump to supply water out of the rai...

Page 13: ...lly connected Ensure that it is isolated from electrical supply during installation and any subsequent service work Unit should only be serviced by qualified personnel or licensed service agent OFF 6 If rainwater is detected the system will revert to normal operation 7 If no rainwater is detected then the switching unit will go to a further 7 day lock out as per step 4 The unit will continue to au...

Page 14: ...k maximum run time setting OVER CURRENT Error Code 3 Over current detected measured current exceeds 10amps 1 Check pump for mechanical resistance Refer to troubleshooting in pump manual 2 Check pump motor for electrical faults Refer to troubleshooting in pump manual NO PUMP CONNECTED CHECK FUSE Error Code 4 No load detected 1 Check to make sure the pump is connected 2 Check for blown fuse on the b...

Page 15: ...ater 3 Remove pump barrel union 4 Inspect clean replace filter Pump is not primed 1 Open gate valve and prime the pump Refer to pump manual on how to prime the pump 2 Reset the switching unit by pressing Reset key SYMPTOM CAUSE SOLUTION Pump continually runs or cycles on and off consistently over time when no outlets open Leak in the plumbing system 1 Identify where the leak is e g toilet or tap l...

Page 16: ...atives or an authorised customer service workshop and any attempt to repair the device by the customer or unauthorised third parties shall terminate the warranty WARRANTY CONDITIONS The warranty will apply only under all the following conditions The pump has been installed by a qualified licensed personnel The pump is returned in good condition and has not arrived damaged The pump is located so th...

Page 17: ......

Reviews: