7
6
VADA FLOW BOSS
DIGITAL WATER SWITCHING UNIT
VFB-DSU
INSTALLATION MANUAL
INSTALLATION
PREPARING FOR INSTALLATION
For successful installation, ensure you have all pieces required for your product combination.
What we’ve supplied:
What you’ll need to supply:
Vada Flow Boss
Digital Water
Switching Unit
Fittings to suit
Pressure
reduction valve*
Suction pipe
(internal diameter
must be no smaller
than 25mm)
x2 mesh
inline filters
Discharge pipe
(internal diameter
must be no smaller
than 25mm)
16mm hole saw
Thread tape
Access to a 10A
outdoor power point
Inline filter AKA
Y-Strainer
Isolation valve
Swing check valve
Float switch tank
*If the incoming mains pressure to your property is greater than the specified 1000 kPa (10 bar),
you MUST fit a pressure reduction valve of appropriate capacity upstream of the VFB-DSU. The
recommended pressure is 500kPa as per AS/NZS 3500.
Pump cover
Barrel union kit