background image

The pump is designed to be used with clean water 

in a residential application. Do not use it with 

alternative fluids, specifically abrasive, corrosive 

or explosive fluids. Do not install or operate your 

pump in an explosive enviroment or near 

combustible matter.

Liquid may be HOT, release pressure with care 

before servicing.

The pump operator or owner must be provided 

with this owner’s manual. This must be read before 

operation, and followed during operation.

DO NOT RUN PUMP DRY

Ensure that your pump is submerged in water 

before operating.

Pump should only be serviced by qualified 

personnel. For best results, use only genuine ser-

vice parts. Be sure to prime pump before starting.

To avoid dangerous or fatal electrical shock hazard, 

turn OFF power to motor and remove plug from 

power outlet before working on pump or motor.

OPERATION

SERVICE AND MAINTENANCE

GENERAL CARE AND MAINTENANCE

Under normal conditions V75-S pumps do not need any type of maintenance. In order to avoid possible failures, it is advisable to periodically 

check the pressure supplied and current absorption. A decrease in pressure is a symptom of wear. An increase in current absorption is a sign of 

abnormal mechanical friction in the pump and/or motor.

If the pump is not going to be used for long periods of time it should be emptied completely, rinsed with clean water and put in a dry place.

Cleaning the filter

If the sucked water is not perfectly clean, it may be necessary to clean the filter with a steel brush to scrape the dirt accumulated on the external 

surface. It is also possible to clean the internal section of the filter. Loosen the screw that fixes the filter to the body of the electropump and 

remove it. Scrape the dirt with a steel brush and rinse it with clean water. If this is not sufficient, have the hydraulic parts cleaned by an 

authorised centre.

START-UP/OPERATION

Open all valves in the suction and discharge lines.  When the power is turned on, the pump will start to pump water.  Without an Auto Pressure 

Control or Mains Water Switch-Over Device, the pump will continue to operate until the power is switched off.

Most applications will incorporate an Auto Pressure Control or Mains Water Switch-Over Device which will stop the pump as soon as it has 

pressurised the system it is connected to. For instructions on operating your pump with one of these devices, please refer to the manual that 

came with your unit.

The system is now ready for use. If no water is delivered, check the troubleshooting section.

VADA - V75-S

Summary of Contents for V75-S

Page 1: ...V75 S Submersible Pump Instruction Manual...

Page 2: ...without float MOTOR Dry motor with stainless steel casing cooled by pumped liquid Level of protection IP 68 Class F insulation Single phase power supply with capacitor permanently activated Thermal p...

Page 3: ...bsorbed power Voltage Amp F No Stages Q L 1 0 20 40 60 80 HP kW HP kW m3 h 1 2 2 4 3 6 4 8 V75 S 0 8 0 6 1 0 75 1 220 240V 3 3 16 8 Discharge head in meters 56 49 8 38 1 19 Model Dimensions mm Weight...

Page 4: ...ced by the manufacturer it s service agent or similarly qualified persons in order to avoid a hazard Children should be supervised do ensure they do not play with the appliance Only qualified licensed...

Page 5: ...f the pump by an appropriate safety factor All pipe work should be supported independently of the pump VADA V75 S ELECTRICAL INSTALLATION This appliance is not intended for use by persons including ch...

Page 6: ...n is a sign of abnormal mechanical friction in the pump and or motor If the pump is not going to be used for long periods of time it should be emptied completely rinsed with clean water and put in a d...

Page 7: ...at the joints are airtight Check that the level of liquid has not dropped below the minimum priming level The pump rotates in the wrong direction Reset the direction of rotation Suction grid blocked C...

Page 8: ...istered trade people The manufacturer distributor reserves the right to vary specifications or delete models from their range without prior notification Dimensions and set outs listed are correct at t...