TROUBLE SHOOTING GUIDE

Symptom

Cause

Remedy

The motor will not start, no water is pumped

No electricity

Ensure that the pump is connected to a live 

outlet

Motor protection tripped

Verify the cause and reset the switch.  If the 

thermal circuit breaker has tripped wait for the 

system to cool down

Defective condenser

Replace the condenser

Shaft blocked

Verify the cause and unblock the pump

The motor runs but no water is pumped

The pump is sucking air

Make sure that the joints are airtight

Check that the level of liquid has not dropped 

below the minimum priming level.

The pump rotates in the wrong direction

Reset the direction of rotation

Suction grid blocked

Clean the suction grid

Check valve blocked

Clean or replace valve

The pump stops after running for a short pe-

riod of time because the thermal motor circuit 

breaker trips

The power supply does not conform with the 

data on the nameplate

Check the voltage on the power supply cable 

leads

A solid object is blocking the impellers

Call 1800 032 566 for your nearest Reece 

branch

The liquid is too thick

See your local Reece branch for an alternative 

pump

VADA - V75-S

Summary of Contents for V75-S

Page 1: ...V75 S Submersible Pump Instruction Manual...

Page 2: ...without float MOTOR Dry motor with stainless steel casing cooled by pumped liquid Level of protection IP 68 Class F insulation Single phase power supply with capacitor permanently activated Thermal p...

Page 3: ...bsorbed power Voltage Amp F No Stages Q L 1 0 20 40 60 80 HP kW HP kW m3 h 1 2 2 4 3 6 4 8 V75 S 0 8 0 6 1 0 75 1 220 240V 3 3 16 8 Discharge head in meters 56 49 8 38 1 19 Model Dimensions mm Weight...

Page 4: ...ced by the manufacturer it s service agent or similarly qualified persons in order to avoid a hazard Children should be supervised do ensure they do not play with the appliance Only qualified licensed...

Page 5: ...f the pump by an appropriate safety factor All pipe work should be supported independently of the pump VADA V75 S ELECTRICAL INSTALLATION This appliance is not intended for use by persons including ch...

Page 6: ...n is a sign of abnormal mechanical friction in the pump and or motor If the pump is not going to be used for long periods of time it should be emptied completely rinsed with clean water and put in a d...

Page 7: ...at the joints are airtight Check that the level of liquid has not dropped below the minimum priming level The pump rotates in the wrong direction Reset the direction of rotation Suction grid blocked C...

Page 8: ...istered trade people The manufacturer distributor reserves the right to vary specifications or delete models from their range without prior notification Dimensions and set outs listed are correct at t...

Reviews: