SERVICE & MAINTENANCE
Under normal conditions, the Vada Flow
Boss Horizontal Multistage Pump VFB-HM110
requires low maintenance and is simple
to service.
To avoid possible failures, we recommend
periodically checking the flow and pressure
supplied and current absorption:
• A decrease in pressure is a symptom of wear.
• An increase in current absorption is a sign
of abnormal mechanical friction in the pump
and/or motor which may be caused by
debris caught in the impeller.
Cleaning the in-line filter
To avoid a build-up of debris and dirt, Vada
recommends cleaning out the in-line filter
once every 6 months, or as required. To do so,
follow the steps below.
1. Isolate all water supplies and remove the
internal strainer.
2. Use a steel brush to clean the dirt from
the filter.
3. Rinse with clean water and reassemble.
Liquid may be HOT, release
pressure with care before servicing.
Pump should only be serviced
by qualified personnel. For best
results, use only genuine service
parts. Be sure to prime pump
before starting.
Turn off power to motor and
remove plug from power outlet
before working on pump or motor.