GENERAL INFORMATION
SIMPLWINDOWS NAME:
Vaddio ClearVIEW HD-18 Camera Control v1.0
CATEGORY:
Camera
VERSION:
v1.0
SUMMARY:
This module will control the Vaddio ClearVIEW HD-18 via RS232.
GENERAL NOTES:
This module provides control, real-time feedback from camera, and will also set
various advanced settings. It can have up to 16 presets. Press and hold preset x
input for 2 seconds and the position of camera will save onto that preset number.
There is also a reset mode that when toggled on will erase any preset number when
pressed afterwards.
If multiple units are daisy-chained then it will be necessary to pulse the
Set_Addresses input. This will set the address of each camera.
CRESTRON HARDWARE REQUIRED:
C2I-COM, ST-COM, C2-COM-*
SETUP OF CRESTRON HARDWARE:
RS232
Baud:9600
Parity: None
Data Bits: 8
Stop Bits: 1
VENDOR FIRMWARE:
Unknown
VENDOR SETUP:
DIP switch 4 should be up for the baud rate of 9600.
CABLE DIAGRAM:
A DB-9 to RJ-45 adapter is supplied with the camera for RS-232.
CONTROL:
Send_Address_Set
D
Pulse to set the addresses of the camera.
Power_<On/Off>
D
Pulse to turn the camera on or off.
Pan_Tilt_*
D
Press and hold to pan and tilt the camera.
Tilt_Speed
A
Analog signal to allow the tilt speed to be adjusted. Valid range is 0d to 14d.
Tilt_Speed_<Up/Down>
D
Pulse to adjust the tilt speed.
Tilt_Speed_Default
D
Pulse to set the tilt speed to the default value of 7d.