background image

 

WallVIEW PRO HD1 Installation and User Guide 341-661 Rev. D                                   Page 2 of 14 

UNPACKING: 

Carefully remove all of the parts from the packaging and identify the following parts: 

  One (1) - Sony EVI-HD1 High Definition PTZ Camera  

  One (1) - Vaddio EZ Interface Module (EZIM) 

  One (1) - Vaddio EZIM to HD Break-out Cable 

  One (1) - Vaddio Quick-Connect PRO (1-RU Rack Mountable)  

  One (1) - Vaddio Thin Profile PRO HD1 Wall Mount 

  One (1) - Sony IR Remote Control 

  One (1) - EZCamera Control Adapter 998-1001-232 (RJ-45 to DB-9F) 

  One (1) - 36V PowerRite™ HD Power Supply with AC Cord Set  

  One (1) - 2-position Phoenix Connector for IR 

 Mounting 

Hardware 

 Documentation 

ƒ

 Vaddio 

Manual 

ƒ

  Sony EVI-HD1 Manual  

 

Optional Accessories:

 

SD Break-out cable (for SD video configurations) - Part # 440-6204-000 

 

 

 

TANDBERG Codec RJ-45 to DB-9 Adapter – Part # 998-1002-232 

 

 

 

RS-232 and IR Adapter for Polycom 8000 & 7000 Series Codecs - Part # 998-1006-232  

 

INSTALLATION 

All WallVIEW products are specifically designed for installation on a vertical wall surface with Cat. 5 cable 
connectivity for Power, Video and Control signaling. Installation is simplified in that no custom 8-Pin mini-din 
cables or expensive S-Video plenum cables are needed and power outlets are not required near the camera 
bracket. All cabling is routed to the head-end using Cat.5 cables.  NOTE:  All RJ-45 connectors need to be 
terminated TIA/EIA 568B or A.  The use of RJ-45 “EZ” connectors is not recommended.  

 

 

Before Installing 

  Locate the camera mounting position paying close attention to camera viewing angles, lighting conditions, 

possible line of site obstructions, and checking for in-wall obstructions. Pick a location to optimize the 
performance of the camera.   

  Pre-wire all cabling from the camera location to the equipment head-end.  

  The Thin Profile Wall Mount for the WallVIEW HD1 can be mounted directly to a 2-gang wall box or can 

be mounted to the drywall using four dry wall anchors.  

 

Wiring Diagram with HDX 9000 Series Codec:  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Component Video (Y, Pb, Pr) 
 to HD codec or other device 

36 VDC  
Power Supply 

IR Output 
(See page 7) 

WallVIEW HD1 with Camera, 
Wall Mount and EZIM  

Quick-Connect Pro 

Up to 500’ (152.4m) of Cat. 5 
for Power, Video and Control 

Power Cat. 5 

Video Cat. 5 

Figure 2: 

The WallVIEW HD1 connected to an HDX 9000 series codec uses the standard RJ-45 to DB-9 adapter 

supplied with the system and DB9 M-M gender changer (not supplied)

 

for control between the camera and codec 

breakout cable.  IR is fed out of the Quick-Connect rack mount unit to the IR port on the back of the HDX 9000 series 
codec for IR forwarding from the camera.  The Power, Video and Control Cat. 5 cables can be run up to 500’ 
(152.4m) from the Quick-Connect box to the EZ Interface Module, which connects to the camera.  See Step 9 for 
additional information on HDX 9000 IR wiring.   

RS-232 DB-9F Adapter with 
Gender Changer 

Y-C and Composite SD video outputs 

(using optional SD break out cable – will 
not output simultaneous HD and SD video) 

Polycom HDCI 
Adapter Cable 

Summary of Contents for WALLVIEW PRO HD1

Page 1: ...for Cat 5 cabling Y Gain adjustment and the EZ Interface Module EZIM Like all Vaddio WallVIEW systems the Thin Profile Wall Mount and mounting hardware is included INTENDED USE Before installing the Vaddio WallVIEW PRO HD1 Camera System please read the entire manual thoroughly All Vaddio camera systems are designed for use indoors Outdoor operation is not recommended has not been tested and could ...

Page 2: ...onnectors is not recommended Before Installing Locate the camera mounting position paying close attention to camera viewing angles lighting conditions possible line of site obstructions and checking for in wall obstructions Pick a location to optimize the performance of the camera Pre wire all cabling from the camera location to the equipment head end The Thin Profile Wall Mount for the WallVIEW H...

Page 3: ... codec IR signals are fed from the HD1 camera to the Quick Connect rack mount unit see Step 9 for additional information on wiring the HDX 7000 8000 codecs The Power Video and Control Cat 5 cables can be run up to 500 from the Quick Connect box to the EZ Interface Module which connects to the camera Up to 500 152 4m of Cat 5 for Power Video and Control RS 232 Cat 5 Video Cat 5 Power Cat 5 Quick Co...

Page 4: ... MXP codec and utilizes an Optional RJ 45 to DB 9 adapter for PTZ control between the HD1 and codec IR signals are fed from the HD1 camera to the Quick Connect rack mount unit to the TANDBERG codec via an IR probe not supplied see Step 7 for additional information The Power Video and Control Cat 5 cables can be run up to 500 from the Quick Connect box to the EZ Interface Module which connects to t...

Page 5: ... 97 B 720p 25 4 480i 59 94 LB C 576i 50 LB 5 480i 59 94 CR D 576i 50 CR 6 480i 59 94 SQ E 576i 50 SQ 7 F Step 3 Connect the 25 pin cable to the EZIM Next mount the EZIM and break out cable to the back of the wall mount using the two tapped screw holes see Figure 6 System Select 0 1080i 59 94 8 1080i 50 1 1080p 29 97 9 1080p 25 2 720p 59 94 A 720p 50 3 720p 29 97 B 720p 25 4 480i 59 94 LB C 576i 50...

Page 6: ...nect PRO rack mount interface Connect the BNC video output connectors either HD or SD depending on where the SYSTEM SELECT rotary switch was set in Step 2 Connect the PowerRite 36 VDC power supply to the Quick Connect PRO power input Note Plugging the POWER Cat 5 Cable into the wrong RJ 45 may cause damage to the camera system and void the warranty Step 8 The Quick Connect PRO interface has an 8 p...

Page 7: ...terminate the single wire coming out of the back of the adapter and connect it to the Phoenix type connector supplied with the Quick Connect PRO The wire needs to be terminated to the Signal SIG pin on the back of the Quick Connect PRO Step 9 For TANDBERG Video Switch IR Pass Thru If connecting a Xantech IR Probe to the IR output of the Quick Connect Pro the white striped wire on the probe should ...

Page 8: ...ng with Sony Vaddio Polycom and TANDBERG remote controls IMPORTANT NOTE The IR Gain adjustment is factory set for distances below 300 feet 91 4 meters and should not have to be adjusted unless the Cat 5 cabling distance is over this length For cable runs above 300 feet slowly adjust the gain level up while pressing functions on the remote control pointed at the HD1 camera using the WallVIEW PRO sy...

Page 9: ...EVI D70 EVI D100 also in SD Mode Polycom EagleEye Max Cat 5 Cable Distance Up to 500 152 4m for Video Power and Control Power Supply 36 VDC 2 78 Amp Dimensions 1 RU Rack Mount 1 75 H x 19 W x 6 D EZCamera Interface Module Connectors Four 4 RJ 45 Connectors One DB 25 for Power Video Control IR Cable Assemblies For Sony HD Cameras DB 25M to DB 15HD 8 Pin Mini Din x 2 EIAJ4 Power Connector For Sony S...

Page 10: ...e RS 232 OUT Connector Pin Signal 1 DSR Sony Daisy chain from DTR 2 DTR Sony Daisy chain to DSR 3 Unused 4 Unused 5 Unused 6 Digital GND 7 TXD to RXD of control source 8 RXD from TXD of control source Video Connector Pin Signal SD HD 1 IR IR 2 IR GND IR GND 3 Y Y 4 C PB 5 C PB 6 Y Y 7 Comp Video PR 8 Comp Video PR DB 25 Connector Pins Signal 1 GND Out 14 RXD Out 2 TXD Out 15 DTR Out 3 DSR Out 16 G...

Page 11: ... OUT 8 Unused RS 232 IN Connector 8 Pin Mini Din Pin Signal 1 DTR 2 DSR 3 TXD 4 GND 5 RXD 6 GND 7 Unused 8 Unused Sony HD Video analog component Pin outs Video Output Connector DB 15HD Pin Signal 1 PR 2 Y 3 PB 4 GND 5 GND 6 GND 7 GND 8 GND 9 NC 10 Unused 11 Unused 12 Unused 13 Unused 14 Unused 15 Unused Power Connector Pin Signal 1 Power 2 Power 3 Power 4 Power 5 Power 6 Power 7 Power 8 Power Vide...

Page 12: ...y to operate this equipment ICES 003 Compliance This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le présent appareil numérique n emet pas de bruits radioélectriques dépassant les limites applicables aux appareils numeriques de la classe A préscrites d...

Page 13: ...at support vaddio com or online at www vaddio com Return Material Authorization RMA number Before returning a product for repair or replacement request an RMA from Vaddio s technical support Provide a technician with a return phone number e mail address shipping address and product serial numbers and describe the reason for repairs or returns as well as the date of purchase and proof of purchase I...

Page 14: ...FAX 763 971 4464 www vaddio com 2008 Vaddio All Rights Reserved Reproduction in whole or in part without written permission is prohibited Specifications and pricing subject to change Vaddio WallVIEW HSDS Quick Connect EZIM and PowerRite are registered trademarks of Vaddio All other trademarks are property of their respective owners Document Number 341 661 Rev D ...

Reviews: