WallVIEW PRO HD1 Installation and User Guide 341-661 Rev. D                                   Page 7 of 14 

Step 9:  For HDX 9000 Series Installs Requiring IR Pass-Thru 

Connect a two-conductor wire to the connectors of both the 
Polycom HDX codec and Quick-Connect Universal PRO rack 
mount box.  Ground from the Universal PRO should be 
terminated to the “-“ port on the HDX 9000 Series codec’s IR input.  
The SIG port on the Universal PRO should be terminated to the 
square wave symbol.  See adjacent drawing for additional detail 

 

Connect the IR output from the Quick-Connect Universal PRO to 
either the IR spring cage IR input on an HDX series codec (where 
available) or a Xantech™ IR probe (compatible models: 282MRP 
or 283M).  The white striped wire on the IR Probe is the Signal 
and the black wire is Ground.   

 
 
 
 
 
 
 
 
 
Step 9:  For HD1 IR Pass-Thru on HDX 7000 and 8000 Series Codecs 

Using the Optional RJ-45 to DB-9 adapter (998-1006-232) with the system, strip and terminate the single wire 
coming out of the back of the adapter, and connect it to the Phoenix-type connector supplied with the Quick-
Connect PRO.  The wire needs to be terminated to the Signal “SIG” pin on the back of the Quick-Connect 
PRO.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Step 9:  For TANDBERG Video Switch IR Pass-Thru 

If connecting a Xantech IR Probe to the IR output of the Quick-
Connect Pro, the white striped wire on the probe should be 
connected to the signal “SIG” terminal and the ground, or black 
wire to “GND”. Attach the probe over the IR window of the codec. 
Make sure the dipswitch is in the correct position

 

 
 
 
 
 
 
 

Figure 9:

  Wiring Configuration for 

IR Forwarding feature

 

(optional)

 

Figure 10:

  Required wiring configuration 

for IR Forwarding from the camera IR 
port to codec.  Note:  There is no IR port 
on the front of the HDX 7000 and 8000 
series codecs.  The IR receiver on these 
codecs is imbedded in the camera.  

 

RS-232 Cat. 5 

Single wire from the back of the Optional 
RJ-45 to DB-9 adapter (998-1006-000), 
connected to the IR “SIG” (signal) port via a 
Phoenix-type connector 

Figure 11: 

Terminating Xantech 

Probe cable to 2-position Phoenix 
type connector 

Summary of Contents for WALLVIEW PRO HD1

Page 1: ...for Cat 5 cabling Y Gain adjustment and the EZ Interface Module EZIM Like all Vaddio WallVIEW systems the Thin Profile Wall Mount and mounting hardware is included INTENDED USE Before installing the Vaddio WallVIEW PRO HD1 Camera System please read the entire manual thoroughly All Vaddio camera systems are designed for use indoors Outdoor operation is not recommended has not been tested and could ...

Page 2: ...onnectors is not recommended Before Installing Locate the camera mounting position paying close attention to camera viewing angles lighting conditions possible line of site obstructions and checking for in wall obstructions Pick a location to optimize the performance of the camera Pre wire all cabling from the camera location to the equipment head end The Thin Profile Wall Mount for the WallVIEW H...

Page 3: ... codec IR signals are fed from the HD1 camera to the Quick Connect rack mount unit see Step 9 for additional information on wiring the HDX 7000 8000 codecs The Power Video and Control Cat 5 cables can be run up to 500 from the Quick Connect box to the EZ Interface Module which connects to the camera Up to 500 152 4m of Cat 5 for Power Video and Control RS 232 Cat 5 Video Cat 5 Power Cat 5 Quick Co...

Page 4: ... MXP codec and utilizes an Optional RJ 45 to DB 9 adapter for PTZ control between the HD1 and codec IR signals are fed from the HD1 camera to the Quick Connect rack mount unit to the TANDBERG codec via an IR probe not supplied see Step 7 for additional information The Power Video and Control Cat 5 cables can be run up to 500 from the Quick Connect box to the EZ Interface Module which connects to t...

Page 5: ... 97 B 720p 25 4 480i 59 94 LB C 576i 50 LB 5 480i 59 94 CR D 576i 50 CR 6 480i 59 94 SQ E 576i 50 SQ 7 F Step 3 Connect the 25 pin cable to the EZIM Next mount the EZIM and break out cable to the back of the wall mount using the two tapped screw holes see Figure 6 System Select 0 1080i 59 94 8 1080i 50 1 1080p 29 97 9 1080p 25 2 720p 59 94 A 720p 50 3 720p 29 97 B 720p 25 4 480i 59 94 LB C 576i 50...

Page 6: ...nect PRO rack mount interface Connect the BNC video output connectors either HD or SD depending on where the SYSTEM SELECT rotary switch was set in Step 2 Connect the PowerRite 36 VDC power supply to the Quick Connect PRO power input Note Plugging the POWER Cat 5 Cable into the wrong RJ 45 may cause damage to the camera system and void the warranty Step 8 The Quick Connect PRO interface has an 8 p...

Page 7: ...terminate the single wire coming out of the back of the adapter and connect it to the Phoenix type connector supplied with the Quick Connect PRO The wire needs to be terminated to the Signal SIG pin on the back of the Quick Connect PRO Step 9 For TANDBERG Video Switch IR Pass Thru If connecting a Xantech IR Probe to the IR output of the Quick Connect Pro the white striped wire on the probe should ...

Page 8: ...ng with Sony Vaddio Polycom and TANDBERG remote controls IMPORTANT NOTE The IR Gain adjustment is factory set for distances below 300 feet 91 4 meters and should not have to be adjusted unless the Cat 5 cabling distance is over this length For cable runs above 300 feet slowly adjust the gain level up while pressing functions on the remote control pointed at the HD1 camera using the WallVIEW PRO sy...

Page 9: ...EVI D70 EVI D100 also in SD Mode Polycom EagleEye Max Cat 5 Cable Distance Up to 500 152 4m for Video Power and Control Power Supply 36 VDC 2 78 Amp Dimensions 1 RU Rack Mount 1 75 H x 19 W x 6 D EZCamera Interface Module Connectors Four 4 RJ 45 Connectors One DB 25 for Power Video Control IR Cable Assemblies For Sony HD Cameras DB 25M to DB 15HD 8 Pin Mini Din x 2 EIAJ4 Power Connector For Sony S...

Page 10: ...e RS 232 OUT Connector Pin Signal 1 DSR Sony Daisy chain from DTR 2 DTR Sony Daisy chain to DSR 3 Unused 4 Unused 5 Unused 6 Digital GND 7 TXD to RXD of control source 8 RXD from TXD of control source Video Connector Pin Signal SD HD 1 IR IR 2 IR GND IR GND 3 Y Y 4 C PB 5 C PB 6 Y Y 7 Comp Video PR 8 Comp Video PR DB 25 Connector Pins Signal 1 GND Out 14 RXD Out 2 TXD Out 15 DTR Out 3 DSR Out 16 G...

Page 11: ... OUT 8 Unused RS 232 IN Connector 8 Pin Mini Din Pin Signal 1 DTR 2 DSR 3 TXD 4 GND 5 RXD 6 GND 7 Unused 8 Unused Sony HD Video analog component Pin outs Video Output Connector DB 15HD Pin Signal 1 PR 2 Y 3 PB 4 GND 5 GND 6 GND 7 GND 8 GND 9 NC 10 Unused 11 Unused 12 Unused 13 Unused 14 Unused 15 Unused Power Connector Pin Signal 1 Power 2 Power 3 Power 4 Power 5 Power 6 Power 7 Power 8 Power Vide...

Page 12: ...y to operate this equipment ICES 003 Compliance This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le présent appareil numérique n emet pas de bruits radioélectriques dépassant les limites applicables aux appareils numeriques de la classe A préscrites d...

Page 13: ...at support vaddio com or online at www vaddio com Return Material Authorization RMA number Before returning a product for repair or replacement request an RMA from Vaddio s technical support Provide a technician with a return phone number e mail address shipping address and product serial numbers and describe the reason for repairs or returns as well as the date of purchase and proof of purchase I...

Page 14: ...FAX 763 971 4464 www vaddio com 2008 Vaddio All Rights Reserved Reproduction in whole or in part without written permission is prohibited Specifications and pricing subject to change Vaddio WallVIEW HSDS Quick Connect EZIM and PowerRite are registered trademarks of Vaddio All other trademarks are property of their respective owners Document Number 341 661 Rev D ...

Reviews: