18
17/05/2016
RD 300-400S/C
2.
Control – Seed depth
In order to set or change seed depth, activate the Control function in the
lifting ram by pressing the C button.
Use the lifting ram to change depth.
The sowing depth indicator on the seed hopper shows the actual
seed depth.
When depth-adjustment is finished, press the button again to
deactivate the Control function, otherwise the function switches
off automatically after 30 seconds.
3.
Remote – Adjustment of fertiliser amount (
option
)
Manual feed output.
If you want to start feed output from a stationary position,
e.g. in a corner, or during output verification, press the
button marked in green.
Preselect the speed in the Basic settings menu.
Adjustable seed application rate
Press the plus button to proportionally in
crease the seed rate and minus to reduce it.
Press the ear button to return to the preset
value.
Adjustable fertiliser application rate
Press the plus button to proportionally in
crease the fertiliser rate and minus to reduce
it. Press the middle button to return to the
preset
value.
Proportional
increase/decrease
is done in the calibration menu.
Shut off seed
The lamp lights Red when feed output is taking place. Press the l
button and the lamp switches off and the seed stops moving.
Shut off BioDrill
The lamp lights Green when feed output is taking place. Press the ll
button and the lamp switches off and BioDrill output stops moving.
4.
Bout marker arms
Manual selection of bout marker –
Left, Right, Both or no bout
marker.
Automatic marker selection
The lamp lights when automatic
operation is engaged.
Indicator lights to show
which bout marker is
activated.
In this case, the left bout