5.18.3 Draining condensed water:
Before the fan is used at the beginning of a new season and when the fan has not been used for a
long time, condensed water should be drained from the tank.
!
Place the equipment to allow the tank to rest at an angle towards the drain at the bottom.
!
Remove the drain hose (B) from the coupling at the bottom of the tank (hold the nipple in po-
sition with a wrench when the hose is loosened), and drain water from the system.
!
Refit the hose and tighten the coupling, but not too hard.
Start-up after filling up oil or replacing the oil and filter:
After having filled up or replaced the oil, air will be mixed with the oil. To avoid damaging the
pump and engine, the air must be removed before the system is allowed to run at full power.
!
Start the fan with the tractor at idle power.
!
Listen to the fan and wait until it operates smoothly.
!
If air bubbles are noticed in the inspection glass, let the fan operate for a while longer at idle
power.
!
Increase the fan speed to about 3000 rpm.
!
Listen to the fan and wait until it operates smoothly.
!
The fan can then be operated at normal power.