Instructions and settings
42
Ver.07/06/01 07/06/01
3.15 Adjusting the air-flow
3.15.1 Mechanical fan, Mfg. No. -10 158
Figure 3.35
The air-flow is regulated by a draught damper.
1/1: The damper is fully open. This setting must always be used. The only possible exception to
this is for very light grass seed, in which case a reduced air-flow can be required.
NOTE!
Oilseeds must always be sown with the damper open, position 1/1.
3.15.2 Hydraulic fan, Mfg. No. -10 158
Figure 3.36
The air quantity is controlled by the fan rev speed which is set using the rev speed regulator (A)
on the fan support. On tractors with a constant pressure hydraulic system, the rev speed regulator
(A) is set to its highest value and the fan rev speed is then adjusted using the flow valve on the
hydraulic system of the tractor.
The fan rev speed is monitored using the rev counter supplied (-10 000) or the Control Box
(10 000-).
The nominal rev speed is 4300 rpm and should under no circumstances fall below 4000 rpm as
this can cause a stoppage in the feed system.