Maintenance and service
80
Ver.3 29/06/07
4.13 Changing the seals on the hydraulic rams
Figure 4.22
NOTE!
During service work on the hydraulic system, the wing sections and the drill must be fully
lowered, with no pressure in their hydraulic systems. Before service work on the folding and
weight transfer systems, see
”4.15 Bleeding the hydraulic system accumulators” on page 82.
Remove the rams completely from the drill before changing the seals.
4.13.1
Changing the seals on the master and slave rams
The following applies to the lifting and tool bar systems.
A
Loosen and unscrew the piston rod guide (A) using the special key (B).
B
Pull out the piston rod and change the seals.
NOTE!
Be very sure that the seals are facing the
correct way.
C
Carefully check that the collar (C) is free of scratches.
D
Refit the ram.
When changing the seals, clean the transfer grooves/holes with a fine abrasive cloth drawn length-
ways along the ram.
NOTE!
Check that the seals are fitted correctly. If necessary, change the seals on the piston rod
guides (A).
Re-mount the ram on the drill and bleed the master and slave system, see
4.13.2
Changing the seals on other rams
Follow the procedure in
”4.13.1 Changing the seals on the master and slave rams” on page 80.
Note that other rams do not have fixing cuffs or transfer grooves.
Summary of Contents for RAPID RDA S Series
Page 1: ...Ver 3 29 06 07 900236 dk Instruktioner S maskine RAPID serie RDA 600 800 S Nr 12 800 14 799...
Page 2: ...2 Ver 3 29 06 07...
Page 17: ...RDA 600 800 S Ver 3 29 06 07 17...
Page 20: ...Instructions and settings 20 Ver 3 29 06 07 2 8 Horizontal alignment Figure 2 18 A E C D B...
Page 71: ...RDA 600 800 S Ver 3 29 06 07 71 Figure 4 4...
Page 104: ...Appendices 104 Ver 3 29 06 07 6 3 2 Hydraulic diagram RDA 800 S Figure 6 2 444639...
Page 116: ...Appendices 116 Ver 3 29 06 07...
Page 117: ......