7

  Installers/users notes

  

Operating Specifications

Operating Pressure: 
Minimum operating pressure 1 bar
Maximum operating pressure 5 bar

Please read these instructions carefully before starting installation and keep for future 
reference.
Remove all packaging and check the product for missing parts or damage before 
starting installation.
Any alterations made to this product and fittings may infringe water regulations and 
will invalidate the guarantee.
The installation must comply with all Local/National Water Supply Authority 
Regulations/Byelaws and Building and Plumbing (UK:BS6700) Regulations.
We strongly recommend that you use a qualified and registered plumber.
Installer must comply with current regulations.
Please note if installing in an enclosed environment, access should be left for servicing 
and maintenance. No costs relating to inadequate access can be accepted.

  Care of the waste

Our products are finished to the highest standard and due care needs to be taken to 
ensure their looks are retained.
We recommend cleaning all products with a soft damp cloth ONLY and advise strongly 
against the use of ALL cleaning products i.e. powders and liquids.
Use only mild soap and water to clean the surface of your mixer valve and dry wit a 
soft dry cloth.
If the above instructions are not followed this will invalidate your guarantee in the 
event of a problem occurring.

Summary of Contents for WG-81389-C

Page 1: ...ve received from you the completed Guarantee Registration Form Vado accepts no responsibility for any forms lost in the post and returns by registered means is therefore recommended Under this guarantee which is non transferable Vado will at its option repair or replace free of charge any product or replacement part found to be defective The guarantee does not extend to any consequential loss or d...

Page 2: ...g UK BS6700 Regulations We strongly recommend that you use a qualified and registered plumber Installer must comply with current regulations Please note if installing in an enclosed environment access should be left for servicing and maintenance No costs relating to inadequate access can be accepted Care of the waste Our products are finished to the highest standard and due care needs to be taken ...

Page 3: ...ting screw Locking nut Operation Turning the handle anti clockwise closes the plug Turning the handle clockwise opens the plug Assembly and installation 81389 The length of the overflow pipe can be adjusted by pulling apart or pushing together the inner and outer overflow pipes Should you need to reduce the length even more pull the outer overflow out of the collet cut both the outer overflow pipe...

Page 4: ...mall lever at the 12 o clock position secure the handle using the grub screw in the underside and tighten with the supplied allen key push on the screw cover Connect to the supply pipework Overflow waste assembly Retaining nut Rubber seal Overflow housing Handle Inlet elbow Screw cover Inlet elbow Cable to pop up waste Inner overflow pipe Outer overflow pipe Collet Push the seal onto the waste ass...

Reviews: